A novel fritless solid-phase extraction (SPE) microcartridge was designed for combination with sheathless capillary electrophoresis-mass spectrometry (sheathless CE-MS) employing a prototype porous-tip capillary for nanoelectrospray ionization (nanoESI). The inlet of the separation capillary (30μm inner diameter (id), 150μm outer diameter (od)) was inserted in a 4mm long SPE microcartridge (150μm id, 365μm od) packed with a C18 sorbent of 55-105μm particle size. Performance of the SPE-CE-MS system was evaluated using diluted solutions of the three opioid peptides dynorphin A (1-7) (DynA), endomorphin 1 (End1) and met-enkephalin (Met). Sample volumes of 1.5μL were loaded on the SPE microcartridge and the retained peptides were eluted with 22nL of an acidic methanol/water (60:40, v/v) solution. Using a pressure of 50mbar during separation to speed up the analysis, good peptide resolution was obtained with acceptable plate numbers (between 53,000 and 92,000). Intraday relative standard deviations (% RSD) for peptide migration times and peak areas were below 4% and 9%, respectively. The SPE-CE-MS method showed good linearity in the 0.05-5ngmL(-1) range and limits of detection (LODs) were 10pgmL(-1). However, loading a larger volume of sample (8μL), LODs could be decreased down to 2pgmL(-1) (2.2-3.5pM). This represents an improvement of up to 5000-fold with respect to the LODs achieved by sheathless CE-MS without on-line preconcentration demonstrating the potential of on-line SPE for further enhancing sensitivity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2013.12.080 | DOI Listing |
Anal Chim Acta
June 2023
Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques.
View Article and Find Full Text PDFTalanta
July 2023
Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA •UB), University of Barcelona, C/ Martà i Franquès 1-11, 08028 Barcelona, Spain. Electronic address:
An on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry (AA-SPE-CE-MS) method was developed to purify, preconcentrate, separate, and characterize the milk allergenic protein β-lactoglobulin (β-LG) in food samples. The sorbent to pack into the SPE microcartidges was prepared by immobilizing an aptamer against β-LG onto magnetic bead particles. After optimizing the SPE-CE-MS method, the sample (ca.
View Article and Find Full Text PDFAnal Chim Acta
May 2023
Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028, Barcelona, Spain. Electronic address:
On-line aptamer affinity solid-phase extraction direct mass spectrometry (AA-SPE-MS) is presented for the rapid purification, preconcentration, and characterization of α-synuclein (α-syn), which is a protein biomarker related to Parkinson's disease. Valve-free AA-SPE-MS is easily implemented using the typical SPE microcartridges and instrumental set-up necessary for on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry (AA-SPE-CE-MS). The essential requirement is substituting the application of the separation voltage by a pressure of 100 mbar for mobilization of the eluted protein through the capillary towards the mass spectrometer.
View Article and Find Full Text PDFJ Proteome Res
March 2023
Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, Martà i Franquès 1-11, Barcelona 08028, Spain.
In this study, several chromatographic sorbents: porous graphitic carbon (PGC), aminopropyl hydrophilic interaction (aminopropyl-HILIC), and phenylboronic acid (PBA) were assessed for the analysis of glycopeptides by on-line solid-phase extraction capillary electrophoresis mass spectrometry (SPE-CE-MS). As the PBA sorbent provided the most promising results, a PBA-SPE-CE-MS method was developed for the selective and sensitive preconcentration of glycopeptides from enzymatic digests of glycoproteins. Recombinant human erythropoietin (rhEPO) was selected as the model glycoprotein and subjected to enzymatic digestion with several proteases.
View Article and Find Full Text PDFTalanta
October 2021
Department of Analytical Chemistry, University of Valencia, C/Dr. Moliner, 50, 46100-Burjassot, Valencia, Spain. Electronic address:
A hybrid material (nano-metal organic framework@organic polymer, named as nano-MOF@polymer) was applied for the first time as sorbent for on-line solid-phase extraction capillary electrophoresis with ultraviolet detection (SPE-CE-UV). The resulting material was prepared building layer-by-layer a HKUST-1 (Hong Kong University of Science and Technology-1) nano-MOF onto the polymer surface, which allowed controlling the thickness and maximizing the active surface area. The sorbent was widely characterized at micro- and nano-scale to validate the synthesis and to establish the material properties.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!