A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter? | LitMetric

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

J Cardiothorac Surg

Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China.

Published: January 2014

Background: The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) 
Methods: One-hundred and six patients with and without moderate prosthesis-patient mismatch early after implantation of a 17-mm Regent valve at aortic position were included. Both clinical and echocardiographic assessments were performed preoperatively, at discharge and during follow-up period (mean follow-up time 52.6 ± 11.9 months).

Results: The prevalence of moderate prosthesis-patient mismatch was documented in 46 patients (43.4%) at discharge. During the follow-up period, no difference in the regression of left ventricular mass, decrease of transvalvular pressure gradients, mortality and prosthesis-related complications was observed between patients with and without moderate prosthesis-patient mismatch. After adjustment for several risk factors, moderate prosthesis-patient mismatch was associated with increased midterm mortality in patients with baseline left ventricular ejection fraction<50% (HR: 1.80, p=0.02), but with normal prognosis in those with preserved LV function. Younger age (cut off value=65 years) was not an independent predictor of increased midterm mortality and valve-related complications in patients with moderate prosthesis-patient mismatch.

Conclusions: Moderate prosthesis-patient mismatch after aortic valve replacement with a small mechanical prosthesis is associated with increased mortality and adverse events in patients with pre-existing left ventricular dysfunction. Selected patients with small aortic annulus can experience satisfactory clinical improvements and midterm survival after aortic valve replacement with a 17-mm Regent valve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3896805PMC
http://dx.doi.org/10.1186/1749-8090-9-17DOI Listing

Publication Analysis

Top Keywords

moderate prosthesis-patient
8
prosthesis-patient mismatch
8
seventeen-millimeter jude
4
jude medical
4
medical regent
4
regent valve
4
valve patients
4
patients small
4
small aortic
4
aortic annulus
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!