Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction The aim of the study was to propose an ideal plating design for fractures running through the mental foramen. Methods The study compared three plating designs-two four-hole miniplates, 2 × 2-hole three-dimensional (3D) plate, and modified 2 × 2-hole 3D plate (posterior strut removed)-using finite element analysis. Von Mises stresses generated around the plates and bone were measured, as well as the mobility that is generated between the fracture fragments by applying muscle forces to generate bite force in one test and applying a force of 500 N over the premolars and first molar region in the second test. Results Von Mises stress in bone with miniplates measured 9.24 MPa in test 1 and 131.99 MPa in test 2. The stress with unmodified 3D plates measured 34.9 MPa in test 1 and150.03 MPa in test 2. The stress with modified 3D plates measured 24.98 MPa in test 1 and 150.59 MPa in test 2. Von Mises stress on the plates and screws measured 28.23 MPa, 95.97 MPa, 72.93 MPa in test 1 and 458.63 MPa, 779.01 MPa, 742.39 MPa in test 2 on miniplates, unmodified 3D plates, and modified 3D plates, respectively. The fracture mobility generated in the model with miniplates measured 0.001 mm in test 1 and 0.01 mm in test 2 and 0.007 mm and 0.02 mm in the model with unmodified 3D plates in test 1 and in test 2, respectively. In the model with modified 3D plates, the value was 0.001 mm and 0.01 mm in tests 1 and 2, respectively. Conclusion The ideal plate design is the two-plate technique with minimal stress generation on the bone and the hardware. The modified 3D plate has adequate strength to be used in the region but needs to be studied in detail.