A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pediatric supracondylar humerus fractures: effect of bone-implant interface conditions on fracture stability. | LitMetric

Background: Closed reduction and percutaneous fixation with Kirschner wires (KWs) is the standard of care of pediatric supra-condylar humerus fractures (SCHFs). Failure modes leading to loss of reduction are not clear and have not been quantified. Multiple factors may weaken the KW-bone interface bonding conditions. To the best of our knowledge, the possible effect of this decrease on different KW configurations and fracture stability has never been studied.

Purpose: To investigate the effect of bone-KW friction conditions on SCHF post-operative mechanical stability and to formulate clinical guidelines for KW configuration under different conditions.

Methods: Finite element-based model of a fixated SCHF was used to simulate structure stability for two lateral divergent versus crossed lateral and medial KW configurations under varying KW-bone friction conditions.

Results: Finite element simulations demonstrated that crossed KWs provide superior stability compared with the divergent configuration when KW-bone bonding is compromised. When KW-bone bonding conditions are adequate, crossed and divergent KW configurations provide similar, sufficient fracture stability.

Conclusions: Under normal bone-implant interface conditions, the two diverging lateral KW configuration offers satisfactory mechanical stability and may be the preferred choice of SCHF fixation. When KW-bone bonding is suboptimal, as when one or more of the lateral KWs are re-drilled, addition of a medial KW should be considered in order to improve stability despite risk to ulnar nerve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886359PMC
http://dx.doi.org/10.1007/s11832-013-0533-4DOI Listing

Publication Analysis

Top Keywords

kw-bone bonding
12
humerus fractures
8
bone-implant interface
8
interface conditions
8
fracture stability
8
bonding conditions
8
mechanical stability
8
stability
7
conditions
5
kw-bone
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!