Lever arm dysfunction in cerebral palsy gait.

J Child Orthop

Nuffield Orthopaedic Centre NHS Trust, Windmill Road, Headington, Oxford, OX3 7LD UK.

Published: November 2013

Skeletal structures act as lever arms during walking. Muscle activity and the ground reaction against gravity exert forces on the skeleton, which generate torque (moments) around joints. These lead to the sequence of movements which form normal human gait. Skeletal deformities in cerebral palsy (CP) affect the function of bones as lever arms and compromise gait. Lever arm dysfunction should be carefully considered when contemplating treatment to improve gait in children with CP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3838510PMC
http://dx.doi.org/10.1007/s11832-013-0510-yDOI Listing

Publication Analysis

Top Keywords

lever arm
8
arm dysfunction
8
cerebral palsy
8
gait skeletal
8
lever arms
8
lever
4
dysfunction cerebral
4
gait
4
palsy gait
4
skeletal structures
4

Similar Publications

Background: Operative management of chronic Achilles tendinopathy with large defects can be surgically challenging. Concerns exist regarding transosseous transfer of the flexor hallucis longus (FHL) tendon because of the shortened lever arm of flexion and weakening of the big toe. The aim of this study was to demonstrate the 2-year outcome of transosseous FHL transfer for the treatment of large Achilles tendon defects.

View Article and Find Full Text PDF

Understanding structure-mechanical activity relationships (SMARs) in polymer mechanochemistry is essential for the rational design of mechanophores with desired properties, yet SMARs in noncovalent mechanical transformations remain relatively underexplored. In this study, we designed a subset of diarylethene mechanophores based on a lever-arm hypothesis and systematically investigated their mechanical activity toward a noncovalent-yet-chemical conversion of atropisomer stereochemistry. Results from Density functional theory (DFT) calculations, single-molecule force spectroscopy (SMFS) measurements, and ultrasonication experiments collectively support the lever-arm hypothesis and confirm the exceptional sensitivity of chemo-mechanical coupling in these atropisomers.

View Article and Find Full Text PDF

Patients with knee osteoarthritis (KOA) often have impaired muscle function of the weight-bearing muscles, particularly in the knee and hip joints. This can lead to a significant loss of strength and power and may play a role in the perceived instability of the knee joint. The purpose of this study was to compare the maximum isometric strength of the hip abductor and knee extensor muscles between patients with KOA with and without perceived instability.

View Article and Find Full Text PDF

Effect of archwire size and lever arm length on anterior and posterior teeth movement during en-masse retraction in personalized lingual orthodontics: A 3-dimensional finite element study.

Int Orthod

December 2024

Department of Orthodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China. Electronic address:

Article Synopsis
  • The study aimed to analyze how different archwire sizes and lever arm lengths affect tooth movement during en-masse retraction in lingual orthodontics.
  • Different archwires with specific dimensions and extra torques were tested, and various lever arm lengths were used to exert a consistent force of 1.5N.
  • Results showed that thicker archwires and longer lever arms improved the control and effectiveness of moving anterior teeth while also influencing the positioning of posterior teeth.
View Article and Find Full Text PDF

: The management of residual elbow instability is a challenging and compelling issue for treating physicians. To overcome inherent drawbacks of dynamic external fixators, the internal joint stabilizer (IJS) has been developed, achieving successful results, but it can sometimes cause local tenderness or anesthetic concerns in the subcutaneous layer. In addition, a bulky anconeus can pull the hardware away from the axis of rotation with an increase in the lever arm and potential issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!