A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: three-year results. | LitMetric

Purpose: To compare the incidence and intensity of posterior capsule opacification (PCO) between 2 similar 1-piece foldable hydrophobic acrylic intraocular lenses (IOLs) over 3 years.

Setting: Department of Ophthalmology, Medical University Vienna, Vienna, Austria.

Design: Randomized prospective patient- and examiner-masked clinical trial with intraindividual comparison.

Methods: Patients with bilateral age-related cataract had cataract surgery and implantation of a Tecnis ZCB00 continuous-optic-edge IOL in 1 eye and an Acrysof SA60AT interrupted-optic-edge IOL in the other eye. Postoperative examinations were performed at 6 months and 3 years. Digital retroillumination images were taken of each eye. The amount of PCO (score 0 to 10) was assessed subjectively at the slitlamp and objectively using automated image-analysis software.

Results: The study comprised 54 patients (108 eyes). The mean objective PCO score was 1.3 ± 1.7 (SD) for the continuous-optic-edge IOLs and 0.9 ± 1.3 for the interrupted-optic-edge IOLs (P=.10). Three years postoperatively, a neodymium:YAG (Nd:YAG) capsulotomy was performed in 26.1% of eyes with the continuous-optic-edge IOL and 21.7% with the interrupted-optic-edge IOL (P=.56). There was no significant difference in corrected distance visual acuity, capsulorhexis–IOL overlap, capsule folds, or anterior capsule opacification 3 years after surgery.

Conclusions: Both IOLs had comparable PCO and Nd:YAG rates 3 years postoperatively. The optimized barrier function of the continuous-optic-edge IOL and the material properties of the interrupted-optic-edge IOL seemingly outbalanced the effect on lens epithelial cell migration and proliferation beneath the optic.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2013.06.021DOI Listing

Publication Analysis

Top Keywords

capsule opacification
12
continuous-optic-edge iol
12
interrupted-optic-edge iol
12
posterior capsule
8
hydrophobic acrylic
8
acrylic intraocular
8
intraocular lenses
8
iol eye
8
pco score
8
years postoperatively
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!