Background: Posterior stabilized total knee arthroplasty requires an intercondylar notch to accommodate the cam housing that articulates with the tibial post to create femoral rollback required for deep flexion. The volume of bone resected for the intercondylar notch varies with implant design, and newer designs may accommodate high flexion with less bone resection.

Questions/purposes: This study aims to analyze the bone volume and density resected from the intercondylar notch for three posterior stabilized implants from a single company: a Posterior Stabilized (PS) system, a Hi-Flex system (HF), and a rounded new box-reamer (RB) system and to further assess whether the newer RB with a cylindrical cutting tool would preserve more native bone.

Materials And Methods: Using a computer model, the PS, HF, and RB femoral components were digitally implanted into CT scans of 19 cadaver femurs. Nine cadavers were fit with a size 4 implant, six with size 3, and four with a size 2. The volume of intercondylar bone resected digitally for femoral preparation was measured. Bone density was measured by CT scans in Hounsfield units (HU). A paired t test was used to compare the mean volume of bone resected for each implant.

Results: For the size 4 femurs, the newer RB design removed 8% less intercondylar bone than the PS design (7,832 ± 501 vs. 8,547 ± 377 mm(3), p < 0.001) and 28% less bone than the HF design (7,832 ± 501 vs. 10,897 ± 444 mm(3), p < 0.001). The average HU for size 4 femurs for RB design was 427 ± 72 (PS = 399 ± 69, p < 0.001; HF = 379 ± 66, p < 0.001). For the size 3 femurs, the RB design removed 12% less intercondylar bone than the PS (6,664 ± 786 vs. 7,516 ± 648 mm(3), p < 0.001) and 27% less bone than the HF (6,664 ± 786 vs. 9,078 ± 713 mm(3), p < 0.001). HU for size 3 femurs for the RB design was 452 ± 70 (PS = 422 ± 53, p < 0.1; HF = 410 ± 59, p < 0.01). For the size 2 femurs, the RB design removed 5% less intercondylar bone than the PS (5,730 ± 552 vs. 6,009 ± 472 mm(3), p < 0.01) and 22% less bone than the HF (5,730 ± 552 vs. 7,380 ± 532 mm(3), p < 0.001). HU for size 2 femurs for the RB design was 430 ± 48 (PS = 408 ± 55, p < 0.01; HF = 385 ± 56, p < 0.01).

Conclusions: The newer RB design removes less bone from the intercondylar notch than the classic PS and HF designs in all sizes tested. The bone-conserving cuts incorporated into this newer implant design appear to preserve native bone without compromising design objectives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757483PMC
http://dx.doi.org/10.1007/s11420-013-9340-1DOI Listing

Publication Analysis

Top Keywords

posterior stabilized
16
intercondylar notch
12
bone resected
12
bone volume
8
stabilized total
8
total knee
8
knee arthroplasty
8
volume bone
8
resected intercondylar
8
intercondylar bone
8

Similar Publications

Advancements and Strategies in Robotic Planning for Knee Arthroplasty in Patients with Minor Deformities.

Life (Basel)

November 2024

Sezione di Chirurgia Protesica ad Indirizzo Robotico-Unità di Traumatologia dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza, 25124 Brescia, Italy.

Knee arthroplasty, commonly performed to treat osteoarthritis, necessitates precise surgical techniques for optimal outcomes. The introduction of systems such as the Persona Knee System (Zimmer Biomet, Warsaw, IN, USA) has revolutionized knee arthroplasty, promising enhanced precision and better patient outcomes. This study investigates the application of robotic planning specifically in knee prosthetic surgeries, with a focus on Persona Knee System prostheses.

View Article and Find Full Text PDF

Background: Despite advancements in prosthetic designs and surgical techniques, patellar dislocation remains a rare but significant complication following total knee arthroplasty, with an incidence ranging between 0.15% and 0.5%.

View Article and Find Full Text PDF

The use of an imageless robotic system in revision of unicompartmental knee arthroplasty.

Knee Surg Sports Traumatol Arthrosc

December 2024

Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy.

Purpose: The application of robotics in revision arthroplasty particularly from unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA), is underexplored. The purpose of this study is to describe the surgical technique of an imageless robotic system used in the revision of UKA to TKA and to evaluate short- to mid-term outcomes.

Methods: This prospective study includes 35 patients treated from May 2020 to July 2023.

View Article and Find Full Text PDF

Background: Ultracongruent (UC) total knee replacement (TKR) designs, serving as alternatives to posterior stabilized (PS) and cruciate retaining (CR) designs, lack conclusive evidence regarding posterior femoral rollback. This study aimed to compare intraoperative posterior femoral rollback and maximal knee flexion between UC and PS inserts, addressing the paucity of literature on femoral rollback achieved with UC designs in total knee replacement.

Methods: A consecutive cohort of 20 patients undergoing robotic-assisted primary total knee replacement, posterior femoral rollback and maximal intraoperative knee flexion were assessed.

View Article and Find Full Text PDF

Superior One-year Forgotten Joint Scores with cruciate-retaining mobile bearings versus posterior-stabilized mobile and fixed bearings in a contemporary total knee system.

Knee

December 2024

Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea; Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, South Korea. Electronic address:

Background: Total knee arthroplasty (TKA) mainly involves the femoral, tibial, and bearing implants. Bearings are categorized by posterior cruciate ligament (PCL) status (cruciate-retaining [CR] vs. posterior-stabilized [PS]) and motion (mobile vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!