Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We have investigated the effect of buffer solution composition and pH during the preparation, washing and re-loading phases within a family of acrylamide-based molecularly imprinted polymers (MIPs) for bovine haemoglobin (BHb), equine myoglobin (EMb) and bovine catalyse (BCat). We investigated water, phosphate buffer saline (PBS), tris(hydroxymethyl)aminomethane (Tris) buffer and succinate buffer. Throughout the study MIP selectivity was highest for acrylamide, followed by N-hydroxymethylacrylamide, and then N-iso-propylacrylamide MIPs. The selectivity of the MIPs when compared with the NIPs decreased depending on the buffer conditions and pH in the order of Tris>PBS>succinate. The Tris buffer provided optimum imprinting conditions at 50 mM and pH 7.4, and MIP selectivities for the imprinting of BHb in polyacrylamide increased from an initial 8:1 to a 128:1 ratio. It was noted that the buffer conditions for the re-loading stage was important for determining MIP selectivity and the buffer conditions for the preparation stage was found to be less critical. We demonstrated that once MIPs are conditioned using Tris or PBS buffers (pH7.4) protein reloading in water should be avoided as negative effects on the MIP's imprinting capability results in low selectivities of 0.8:1. Furthermore, acidifying the pH of the buffer solution below pH 5.9 also has a negative impact on MIP selectivity especially for proteins with high isoelectric points. These buffer conditioning effects have also been successfully demonstrated in terms of MIP efficiency in real biological samples, namely plasma and serum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2013.11.052 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!