Pulse-jet bag filters are frequently employed for particle removal from off gases. Separated solids form a layer on the permeable filter media called filter cake. The cake is responsible for increasing pressure drop. Therefore, the cake has to be detached at a predefined upper pressure drop limit or at predefined time intervals. Thus the process is intrinsically semi-continuous. The cake formation and cake detachment are interdependent and may influence the performance of the filter. Therefore, understanding formation and detachment of filter cake is important. In this regard, the filter media is the key component in the system. Needle felts are the most commonly used media in bag filters. Cake formation studies with heat treated and membrane coated needle felts in pilot scale pulse jet bag filter were carried out. The data is processed according to the procedures that were published already [Powder Technology, Volume 173, Issue 2, 19 April 2007, Pages 93-106]. Pressure drop evolution, cake height distribution evolution, cake patches area distribution and their characterization using fractal analysis on different needle felts are presented here. It is observed that concavity of pressure drop curve for membrane coated needle felt is principally caused by presence of inhomogeneous cake area load whereas it is inherent for heat treated media. Presence of residual cake enhances the concavity of pressure drop at the start of filtration cycle. Patchy cleaning is observed only when jet pulse pressure is too low and unable to provide the necessary force to detach the cake. The border line is very sharp. Based on experiments with limestone dust and three types of needle felts, for the jet pulse pressure above 4 bar and filtration velocity below 50 mm/s, cake is detached completely except a thin residual layer (100-200 μm). Uniformity and smoothness of residual cake depends on the surface characteristics of the filter media. Cake height distribution of residual cake and newly formed cake during filtration prevails. The patch size analysis and fractal analysis reveal that residual cake grow in size (latterly) following regeneration initially on the base with edges smearing out, however, the cake heights are not leveled off. Fractal dimension of cake patches boundary falls in the range of 1-1.4 and depends on vertical position as well as time of filtration. Cake height measurements with Polyimide (PI) needle felts were hampered on account of its photosensitive nature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886367PMC
http://dx.doi.org/10.1016/j.powtec.2011.08.037DOI Listing

Publication Analysis

Top Keywords

needle felts
24
cake
23
pressure drop
20
cake height
16
residual cake
16
cake formation
12
heat treated
12
membrane coated
12
coated needle
12
filter media
12

Similar Publications

A New Phosphorous/Nitrogen-Containing Flame-Retardant Film with High Adhesion for Jute Fiber Composites.

Polymers (Basel)

April 2023

The Ministry of Education Key Laboratory of Automotive Material, College of Materials Science and Engineering, Jilin University, Changchun 130025, China.

In this work, a novel P/N flame-retardant monomer (PDHAA) was synthesized through reacting phenyl dichlorophosphate (PDCP) with N-hydroxyethyl acrylamide (HEAA). The structure of PDHAA was confirmed using Fourier transform infrared (FTIR) spectroscopy and proton nuclear magnetic resonance (NMR) spectroscopy. PDHAA monomer and 2-hydroxyethyl methacrylate phosphate (PM-2) monomer were mixed at different mass ratios, to prepare UV-curable coatings, and then applied to the surface of fiber needled felts (FNFs), to improve their flame retardancy.

View Article and Find Full Text PDF

Real-time visualisation of peripheral nerve trauma during subepineural injection in pig brachial plexus using micro-ultrasound.

Br J Anaesth

July 2021

Sunnybrook Research Institute, Toronto, Ontario, Canada; Department of Medical BioPhysics, University of Toronto, Toronto, Canada.

Background: Nerve damage is consistently demonstrated after subepineural injection in animal studies, but not after purposeful injection in patients participating in clinical studies. There is a need to better visualise nerves in order to understand the structural changes that occur during subepineural injection.

Methods: We scanned the brachial plexuses of three anaesthetised pigs using micro-ultrasound imaging (55-22 MHz probe), inserted 21 gauge block needles into the radial, median, and axillary nerves, and injected two 0.

View Article and Find Full Text PDF

High-performance microwave absorption materials combined with good oxidation resistance and mechanical properties are highly desirable in some extreme situations. Herein, three-dimensional (3D) needled carbon fiber felts reinforced silicon oxycarbide (SiOC/CFs) composites with excellent electromagnetic (EM) wave absorption, good oxidation resistance and mechanical properties were successfully prepared through a simple precursor infiltration and pyrolysis (PIP) process. Notably, the EM wave absorption, oxidation resistance and mechanical performances strongly depend on the PIP cycles through adjusting the content of SiOC to control the porosity and density of the composites.

View Article and Find Full Text PDF

Mn/Ce Oxides Decorated Polyphenylene Sulfide Needle-Punching Fibrous Felts for Dust Removal and Denitration Application.

Polymers (Basel)

January 2020

Industrial Research Institute of Nonwovens & Technical Textiles, College of Textiles & Clothing, Qingdao University, Qingdao 266071, China.

Development of a novel filter material is urgently required for replacing the high-cost flue gas purification technology in the simultaneous removal of both fine dust and Nitrogen oxides (NO). In this study; polyphenylene sulfide (PPS) needle-punching fibrous felts (NPFF) were employed as the filter material to remove the fine dust; and in the meanwhile; Mn and Ce oxides were loaded onto the PPS NPFF as the catalyst for selective catalytic reduction of NO with NH. Two different pretreatment methods; i.

View Article and Find Full Text PDF

Despite widespread use of ultrasound imaging to guide needle placement, the incidence of transient and permanent nerve damage as a complication of regional anaesthesia has not changed over the last decade. In view of the controversy surrounding intraneural injection there is a need to understand the structural changes caused by subepineural and subperineural needle penetration. Clinical ultrasound machines do not provide adequate anatomical resolution, and anaesthetists have difficulty judging the precise location of the needle tip relative to the epineurium.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!