Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The electrical conductivity of blood is sufficiently higher than that of myocardium to make feasible the detection of cardiac volume changes by measurement of intraventricular fluid conductance. An eight-electrode catheter was used to inject an alternating current (100 microA or less, at 1500 Hz) via the two electrodes nearest the ventricular base and apex, then the resulting five voltage differences between adjacent pairs of the six intervening electrodes were measured. When current amplitude was held constant, the cross-sectional area of the ventricular cavity slice defined by planes perpendicular to the catheter through the relevant pair of electrodes was inversely proportional (to the first order) to the voltage difference. Measurement of multiple segments compensated for isovolumic cavity shape changes. The technique had previously been shown to measure left ventricular volume successfully, but the geometry of the right ventricle made this measurement more problematical. Using open-chested, anesthetized greyhounds, we compared the catheter-measured right ventricular volume change with stroke volume as measured by a pulmonary arterial electromagnetic blood flowmeter. With optimal catheter placement, good correlation between stroke volume and catheter-measured volume changes was achieved when stroke volume was perturbed on a beat-to-beat basis. In six data records from three dogs, involving two different means of varying stroke volume (rapid injection of blood and sinus node irritation), the correlations yielded r2 values between 0.82 and 0.98.(ABSTRACT TRUNCATED AT 250 WORDS)
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1987.tb06043.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!