Randomized clinical trials support the use of implantable defibrillators for mortality reduction in specific populations at high risk for sudden cardiac death. Conventional transvenous defibrillator systems are limited by implantation-associated complications, infection, and lead failure, which may lead to delivery of inappropriate shocks and diminish survival. The development of a fully subcutaneous defibrillator may represent a valuable addition to therapies targeted at sudden death prevention. The PubMed database was searched to identify all clinical reports of the subcutaneous defibrillator from 2000 to the present. We reviewed all case series, cohort analyses, and randomized trials evaluating the safety and efficacy of subcutaneous defibrillators. The subcutaneous defibrillator is a feasible development in sudden cardiac death therapy and may be useful particularly to extend defibrillator therapy to patients with complicated anatomy, limited vascular access, and congenital disease. The subcutaneous defibrillator should not be considered in patients with an indication for cardiac pacing or who have ventricular tachycardia responsive to antitachycardia pacing. Further investigation is needed to compare long-term, head-to-head performance of subcutaneous defibrillators and conventional transvenous defibrillator systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjmed.2013.10.018DOI Listing

Publication Analysis

Top Keywords

subcutaneous defibrillator
20
sudden death
8
death prevention
8
fully subcutaneous
8
defibrillator
8
sudden cardiac
8
cardiac death
8
conventional transvenous
8
transvenous defibrillator
8
defibrillator systems
8

Similar Publications

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Background: Brugada syndrome (BrS) is an inherited channelopathy characterized by right precordial ST-segment elevation. This study investigates the clinical and genetic characteristics of children with BrS in Hong Kong.

Methods: A retrospective review was conducted at the only tertiary pediatric cardiology center in Hong Kong from 2002 to 2022, including all pediatric BrS patients under 18 years old.

View Article and Find Full Text PDF

Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review.

Cardiol Rev

November 2024

Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan.

A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients.

View Article and Find Full Text PDF

Unlabelled: New cardiac implantable electronic devices (CIEDs), such as leadless pacemakers and subcutaneous implantable cardioverter defibrillators (S-ICDs), are being used in patients with adult congenital heart disease. The selection of CIEDs often requires careful consideration due to technical challenges posed by a unique heart structure. A 27-year-old man following a surgical tetralogy of Fallot (TOF) repair developed non-sustained ventricular tachycardia, sick sinus syndrome, and complete atrioventricular block.

View Article and Find Full Text PDF

A 47-year-old man with congenitally corrected transposition of the great arteries, dextrocardia, heart failure, and pacemaker-dependency presented with nonsustained ventricular tachycardia. He underwent a right-sided transmuscular cardioverter-defibrillator insertion after appropriate testing. One year later, life-saving antiarrhythmic therapy was applied by the subcutaneous defibrillator while the appropriate pacemaker functioning supported heart rhythm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!