[Application of wireless sensor networks in healthcare].

Zhongguo Yi Liao Qi Xie Za Zhi

Dept. of Medical Equipment, the 6th People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, 200233.

Published: September 2013

This paper introduces general architecture of wireless sensor networks architecture and application in healthcare, discusses the application direction which is urgent need to expand in medical field.

Download full-text PDF

Source

Publication Analysis

Top Keywords

wireless sensor
8
sensor networks
8
[application wireless
4
networks healthcare]
4
healthcare] paper
4
paper introduces
4
introduces general
4
general architecture
4
architecture wireless
4
networks architecture
4

Similar Publications

A PEDOT:PSS-based flexible bimodal resonant sensor with independently controllable modes.

Chem Commun (Camb)

January 2025

College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), State Key Laboratory of Organic Electronics and Information Displays, Nanjing University of Posts & Telecommunications (NJUPT), Nanjing, 210023, China.

Traditional sensors struggle in complex human environments, particularly with humidity and strain detection requiring high sensitivity and robust anti-interference. This work introduces a flexible, miniaturized, low-cost dual-mode sensor that combines a novel resonator structure with a chemically modified conducting polymer, enabling simultaneous strain and humidity detection alongside high anti-interference performance sensitivity and wireless transmission.

View Article and Find Full Text PDF

Background: Heart failure (HF) is a chronic, progressive condition where the heart cannot pump enough blood to meet the body's needs. In addition to the daily challenges that HF poses, acute exacerbations can lead to costly hospitalizations and increased mortality. High health care costs and the burden of HF have led to the emerging application of new technologies to support people living with HF to stay well while living in the community.

View Article and Find Full Text PDF

Capacitive dielectric temperature sensors based on polydimethylsiloxane (PDMS) loaded with 10 vol% of inexpensive, commercially-available conductive fillers including copper, graphite, and milled carbon fiber (PDMS-CF) powders are reported. The sensors are tested in the range of 20-110 °C and from 0.5 to 200 MHz, with enhanced sensitivity from 20 to 60 °C, and a relative response of 85.

View Article and Find Full Text PDF

Objective: Common examinations for diagnosing obstructive sleep apnea (OSA) are polysomnography (PSG) and home sleep apnea testing (HSAT). However, both PSG and HSAT require that sensors be attached to a subject, which may disturb their sleep and affect the results. Hence, in this study, we aimed to verify a wireless radar framework combined with deep learning techniques to screen for the risk of OSA in home-based environments.

View Article and Find Full Text PDF

: This study aimed to assess knee joint function in post-stroke patients using wireless motion sensors and functional tests. This type of evaluation may be important for improving gait quality. : The study included 25 post-stroke patients (age 53.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!