Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/aor.12222 | DOI Listing |
J Funct Biomater
December 2024
Adult Spine Orthopaedics Department, W. Dega Orthopaedic and Rehabilitation Clinical Hospital, Poznan University of Medical Sciences, 28 Czerwca 1956 Street 135/147, 61-545 Poznan, Poland.
The prototype of a biomimetic multi-spiked connecting scaffold (MSC-Scaffold) represents an essential innovation in the fixation in subchondral trabecular bone of components for a new generation of entirely cementless hip resurfacing arthroplasty (RA) endoprostheses. In designing such a functional biomaterial scaffold, identifying the microstructural and mechanical properties of the host bone compromised by degenerative disease is crucial for proper post-operative functioning and long-term maintenance of the endoprosthesis components. This study aimed to explore, depending on the occurrence of obesity, changes in the microstructure and mechanical properties of the subchondral trabecular bone in femoral heads of osteoarthritis (OA) patients caused by the MSC-Scaffold embedding.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
December 2024
Société Française de Chirurgie Orthopédique et Traumatologique, 56 rue Boissonade, 75014 Paris Cedex, France.
Introduction: Lower limb length discrepancy (LLD) following hip arthroplasty after proximal femoral fracture (PFFA) is little studied. The aim of this work was to answer the following questions: 1) What are the incidence and mean values of LLD after PFFA? 2) What are the clinical consequences (tolerance) of LLD after PFFA? 3) Can we identify risk factors for LLD after PFFA? 4) Is there a significant difference in terms of LLD after PFFA to treat intra- versus extra-capsular fractures?
Hypothesis: LLD after proximal femoral fracture arthroplasty is rare but has good clinical tolerance, given the low functional demands of the patients.
Patients And Methods: This is a multicenter prospective observational cohort study (15 centers), including 590 patients, operated on for hip arthroplasty for proximal femur fracture between May 2022 and June 2023.
Arch Orthop Trauma Surg
December 2024
Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017, Japan.
Introduction: Thigh pain, aseptic loosening, and failure after total hip arthroplasty has been reported. Therefore, this study examines the impact of femoral stem alignment on periprosthetic bone mineral density (BMD) in THA using the Avenir Complete cementless stem, focusing on the role of precise stem alignment in maintaining proximal femoral BMD.
Materials And Methods: Consecutive patients who received the Avenir Complete stem via mini anterolateral approach in the supine position between March 2019 and March 2022 were included.
Arch Orthop Trauma Surg
December 2024
Department of General Orthopaedics and Tumour Orthopedics, Muenster University Hospital, Albert-Schweitzer-Campus 1, 48149, Muenster, Germany.
Background: Uncemented total hip arthroplasty (THA) is a successful treatment for advanced hip joint diseases. More recently, short stems became increasingly popular, but stem subsidence remains a concern. This study investigates early short stem subsidence in a large patient cohort using a simple measurement approach for everyday practice.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
December 2024
Trauma and Orthopaedics, Royal Free NHS Foundation Trust, Pond Street, London, NW3 2QG, United Kingdom.
Background: Periprosthetic femoral fractures (PFF) are a challenging complication of hip arthroplasty surgery, posing a high risk of morbidity, mortality and reoperation. The Vancouver Classification describes a B2 PFF around a loose stem with sufficient bone stock. In recent years, the number of B2 PFFs and cementation of femoral stems have increased substantially.