Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel.

Biomicrofluidics

Center for Biofluid and Biomimic Research, Pohang University of Science and Technology, Pohang, South Korea ; Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, South Korea.

Published: January 2014

The accurate viscosity measurement of complex fluids is essential for characterizing fluidic behaviors in blood vessels and in microfluidic channels of lab-on-a-chip devices. A microfluidic platform that accurately identifies biophysical properties of blood can be used as a promising tool for the early detections of cardiovascular and microcirculation diseases. In this study, a flow-switching phenomenon depending on hydrodynamic balancing in a microfluidic channel was adopted to conduct viscosity measurement of complex fluids with label-free operation. A microfluidic device for demonstrating this proposed method was designed to have two inlets for supplying the test and reference fluids, two side channels in parallel, and a junction channel connected to the midpoint of the two side channels. According to this proposed method, viscosities of various fluids with different phases (aqueous, oil, and blood) in relation to that of reference fluid were accurately determined by measuring the switching flow-rate ratio between the test and reference fluids, when a reverse flow of the test or reference fluid occurs in the junction channel. An analytical viscosity formula was derived to measure the viscosity of a test fluid in relation to that of the corresponding reference fluid using a discrete circuit model for the microfluidic device. The experimental analysis for evaluating the effects of various parameters on the performance of the proposed method revealed that the fluidic resistance ratio ( R J L / R L , fluidic resistance in the junction channel ( R J L ) to fluidic resistance in the side channel ( R L )) strongly affects the measurement accuracy. The microfluidic device with smaller R J L / R L values is helpful to measure accurately the viscosity of the test fluid. The proposed method accurately measured the viscosities of various fluids, including single-phase (Glycerin and plasma) and oil-water phase (oil vs. deionized water) fluids, compared with conventional methods. The proposed method was also successfully applied to measure viscosities of blood with varying hematocrits, chemically fixed RBCS, and channel sizes. Based on these experimental results, the proposed method can be effectively used to measure the viscosities of various fluids easily, without any fluorescent labeling and tedious calibration procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3739827PMC
http://dx.doi.org/10.1063/1.4816713DOI Listing

Publication Analysis

Top Keywords

proposed method
24
viscosity measurement
12
measurement complex
12
complex fluids
12
microfluidic device
12
test reference
12
junction channel
12
viscosities fluids
12
reference fluid
12
fluidic resistance
12

Similar Publications

In the fields of engineering, science, technology, and medicine, artificial intelligence (AI) has made significant advancements. In particular, the application of AI techniques in medicine, such as machine learning (ML) and deep learning (DL), is rapidly growing and offers great potential for aiding physicians in the early diagnosis of illnesses. Depression, one of the most prevalent and debilitating mental illnesses, is projected to become the leading cause of disability worldwide by 2040.

View Article and Find Full Text PDF

Background: Psychologists have developed frameworks to understand many constructs, which have subsequently informed the design of digital mental health interventions (DMHIs) aimed at improving mental health outcomes. The science of happiness is one such domain that holds significant applied importance due to its links to well-being and evidence that happiness can be cultivated through interventions. However, as with many constructs, the unique ways in which individuals experience happiness present major challenges for designing personalized DMHIs.

View Article and Find Full Text PDF

Epoxides are versatile chemical intermediates that are used in the manufacture of diversified industrial products. For decades, thermochemical conversion has long been employed as the primary synthetic route. However, it has several drawbacks, such as harsh and explosive operating conditions, as well as a significant greenhouse gas emissions problem.

View Article and Find Full Text PDF

Objective: This study aims to address the issue of driving safety on highways in the desert region of Northwest China during extreme weather conditions such as sandstorms, with the goal of reducing driver risk. It explores driver behavior under extreme conditions of sandstorms and sand accumulation, proposing safety speed recommendations and warning models for different environments to calculate the optimal warning distance in windy and sandy conditions.

Methods: Natural driving simulation experiments were conducted in windy and sandy environments, collecting driving behavior data from 45 drivers under varying visibility and road conditions with or without sand accumulation.

View Article and Find Full Text PDF
Article Synopsis
  • The study compared the costs of the current CDC 3-step HIV testing algorithm with a new single-test alternative (cobas) for efficiency in diagnosing HIV.
  • A decision-tree model estimated costs and testing needs for 1 million people, revealing significant reductions in total tests and retests required when using the alternative method.
  • Findings indicate that the new algorithm could simplify HIV testing processes, cut overall testing numbers, and keep healthcare costs stable, thereby improving patient outcomes.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!