A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Delcath Systems' Generation 2 (GEN 2) melphalan hemofiltration system in a porcine model of percutaneous hepatic perfusion. | LitMetric

AI Article Synopsis

  • A new melphalan hemoperfusion filter (GEN 2) was tested in pigs to assess its effectiveness in filtering melphalan during a simulated medical procedure.
  • The filter showed a high efficiency of 99.0% in removing melphalan and maintained a low pressure gradient of 20.9 mmHg, indicating good blood flow.
  • Although some blood components like albumin and platelets decreased during the procedure, the changes are considered manageable in a clinical setting.

Article Abstract

Purpose: A new melphalan hemoperfusion filter (GEN 2) was evaluated in a simulated-use porcine model of percutaneous hepatic perfusion (PHP). The current study evaluated melphalan filtration efficiency, the transfilter pressure gradient, and the removal of specific blood products.

Materials And Methods: A porcine PHP procedure using the GEN 2 filter was performed under Good Laboratory Practice conditions to model the 60-min clinical PHP procedure.

Results: The mean filter efficiency for removing melphalan in six filters was 99.0 ± 0.4 %. The transfilter pressure gradient across the filter averaged 20.9 mmHg for the 60-min procedure. Many blood components, including albumin and platelets, decreased on average from 3.55 to 2.02 g/dL and from 342 to 177 × 10.e3/μL, respectively, during the procedure.

Conclusion: The increased melphalan extraction efficiency of the new filter is expected to decrease systemic melphalan exposure. In addition, the low transfilter pressure gradient resulted in low resistance to blood flow in the GEN 2 filter, and the changes to blood components are expected to be clinically manageable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4024156PMC
http://dx.doi.org/10.1007/s00270-013-0826-5DOI Listing

Publication Analysis

Top Keywords

transfilter pressure
12
pressure gradient
12
porcine model
8
model percutaneous
8
percutaneous hepatic
8
hepatic perfusion
8
gen filter
8
blood components
8
melphalan
6
filter
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!