A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ion-exchange chromatography combined with direct current amperometric detection at CuNPs/reduced graphene oxide-chitosan composite film modified electrode for determination of monosaccharide composition of polysaccharides from Phellinus igniarius. | LitMetric

A novel Cu nanoparticles/reduced graphene oxide-chitosan (CuNPs/r-GO-chitosan) composite film modified glassy carbon electrode (GCE) was fabricated by dispersing CuNPs uniformly on a stable r-GO-chitosan thin film through electrodeposition process. The modified electrode was characterized by cyclic voltammetry, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS), and exhibited efficiently electrocatalytic oxidation toward monosaccharides with high stability. The good electrocatalytic activity of this modified electrode might be attributed to the synergistic effect of r-GO and CuNPs, and the stability might be attributed to the r-GO and chitosan thin matrix film. When the CuNPs/r-GO-chitosan/GCE was used as an electrochemical sensor in high performance anion exchange chromatography-direct current amperometric detection (HPAEC-DC) flowing system for the determination of monosaccharides under constant working potential of +0.55 V, the detection limits (S/N=3) ranged from 0.006 to 0.02 mg L(-1) for the analyzed sugars, and the dynamic linear ranges spanned from 0.02 to 500 mg L(-1). The proposed method has been applied for the determination of monosaccharide composition of crude polysaccharides from phellinus igniarius real samples, and the results were satisfactory.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2013.11.024DOI Listing

Publication Analysis

Top Keywords

modified electrode
12
current amperometric
8
amperometric detection
8
graphene oxide-chitosan
8
composite film
8
film modified
8
determination monosaccharide
8
monosaccharide composition
8
polysaccharides phellinus
8
phellinus igniarius
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!