A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative assessment of global cerebral metabolic rate of oxygen (CMRO2) in neonates using MRI. | LitMetric

The cerebral metabolic rate of oxygen (CMRO2) is the rate of oxygen consumption by the brain, and is thought to be a direct index of energy homeostasis and brain health. However, in vivo measurement of CMRO2 is challenging, in particular for the neonatal population, in whom conventional radiotracer methods are not applicable because of safety concerns. In this study, we propose a method to quantify global CMRO2 in neonates based on arteriovenous differences in oxygen content, and employ separate measurements of oxygenation and cerebral blood flow (CBF) parameters. Specifically, arterial and venous oxygenation levels were determined with pulse oximetry and the novel T2 relaxation under spin tagging (TRUST) MRI, respectively. Global CBF was measured with phase contrast (PC) flow velocity MRI. The proposed method was implemented on a standard 3-T MRI scanner without the need for any exogenous tracers, and the total scan duration was less than 5 min. We demonstrated the feasibility of this method in 12 healthy neonates within an age range of 35-42 gestational weeks. CMRO2 values were successfully obtained from 10 neonates. It was found that the average CMRO2 in this age range was 38.3 ± 17.7 µmol/100 g/min and was positively correlated with age (p = 0.007; slope, 5.2 µmol/100 g/min per week), although the highest CMRO2 value in this age range was still less than half of the adult level. Test-retest studies showed a coefficient of variation of 5.8 ± 2.2% between repeated CMRO2 measurements. In addition, given the highly variable blood flow velocity within this age range, it is recommended that the TRUST labeling thickness and position should be determined on a subject-by-subject basis, and an automatic algorithm was developed for this purpose. Although this method provides a global CMRO2 measure only, the clinical significance of an energy consumption marker and the convenience of this technique may make it a useful tool in the functional assessment of the neonatal population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3970939PMC
http://dx.doi.org/10.1002/nbm.3067DOI Listing

Publication Analysis

Top Keywords

age range
16
rate oxygen
12
cmro2
9
cerebral metabolic
8
metabolic rate
8
oxygen cmro2
8
cmro2 neonates
8
neonatal population
8
global cmro2
8
blood flow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!