We evaluated the diagnostic usefulness of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve dysfunction (PVD) of an ATS valve. Twenty-four patients underwent MDCT following echocardiography and cineradiography. Echocardiography and cineradiography showed normal valve function in 17 patients and PVD in 7. PVD included aortic prosthetic valve obstruction in 4 patients, an aortic annular aneurysm with paraprosthetic regurgitation in one, and a blocked leaflet in the mitral position in 2. Among the 7 patients, 5 received reoperation after MDCT. MDCT revealed a subprosthetic mass in all 5 patients with PVD and in 4 patients with normal valve function in the aortic position. In addition to a subprosthetic mass, an annular aneurysm was found in one. Valvular masses were detected in 2 patients with mitral PVD. At reoperation, subprosthetic pannus in the aortic position was detected in 2 patients, subprosthetic pannus and annular aneurysm with paraprosthetic leaks in one, and mitral valve thrombosis in 2. These findings confirmed at reoperation matched to the findings observed on MDCT. The mean CT attenuation of the subprosthetic mass in 6 patients was 152 ± 12 HU and that of the subprosthetic pannus in 3 patients was 163 ± 17 HU. CT attenuation of the thrombus in the mitral valve in the 2 patients was 60 and 99 HU. Our study demonstrates that MDCT is a valuable and reliable diagnostic technique for PVD in an ATS valve and that MDCT may identify an abnormality causing PVD.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-013-0751-zDOI Listing

Publication Analysis

Top Keywords

annular aneurysm
12
subprosthetic mass
12
subprosthetic pannus
12
patients
11
valve
9
valve dysfunction
8
prosthetic valve
8
pvd ats
8
ats valve
8
echocardiography cineradiography
8

Similar Publications

Background: Mitral annular disjunction (MAD), posterior displacement of the mitral valve leaflet hinge point, predisposes to arrhythmias or sudden cardiac death. We evaluated the burden of MAD, mitral valve prolapse (MVP), and mitral regurgitation (MR) by heritable thoracic aortic disease gene in a cross-sectional analysis of 2014-2023 data in the Montalcino Aortic Consortium registry.

Methods And Results: MAD was determined by direct measurement of echocardiographic images.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the long-term outcomes of two types of rings used in valve-sparing root replacement surgery: a calibrated expansible extra-aortic ring and a homemade Dacron ring.
  • Among 486 patients, those with the extra-aortic ring showed significantly better long-term survival, lower rates of reoperation, and reduced recurrence of severe aortic insufficiency compared to the Dacron ring.
  • The extra-aortic ring also demonstrated superior performance in preventing annular dilation and preserving root expansibility over time.
View Article and Find Full Text PDF

Acute Aortic Dissection After Transcatheter Aortic Valve Replacement.

Am J Cardiol

July 2024

Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania. Electronic address:

Acute aortic dissection (AAD) is a rare and potentially fatal complication associated with transcatheter aortic valve replacement (TAVR). Owing to the paucity of existing institutional data, we sought to assess the incidence of postimplant AAD in patients who underwent TAVR at a single institution. All patients who underwent TAVR from 2013 to 2022 were retrospectively reviewed to identify those who possessed clinical or radiologic evidence of AAD after TAVR.

View Article and Find Full Text PDF

Tricuspid annular disjunction (TAD) is concomitant in approximately half of mitral annular disjunction (MAD) cases. Here we report a case of echocardiographically isolated TAD detected during Takotsubo syndrome (TTS) complicated by a transient aggravation of tricuspid regurgitation. An 87-year-old female was admitted at the emergency department with ST segment elevation.

View Article and Find Full Text PDF

Purpose: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation.

Methods: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!