Reliability of CAD CAM technology in assessing crown preparations in a preclinical dental school environment.

J Dent Educ

College of Dental Medicine, Georgia Regents University, Room GC 3080, 1430 John Wesley Gilbert Drive, Augusta, GA 30912-1290;.

Published: January 2014

In order to use CAD CAM (Computer Aided Design, Computer Aided Manufacturing) technology as an assessment tool when evaluating the preclinical performance of dental students, it is imperative that one has confidence in the reliability of the process. In this study, a variety of alignment methods were compared to determine both the consistency and accuracy of each method. Although the "Tooth Dots Diagonal" method exhibited the best precision (coefficient of variation=5.4 percent), it also represented the least accurate method when compared to the other methods tested. Using "Small Dots Diagonal" on the gingiva appears to be the best option, exhibiting an acceptable coefficient of variation (17.6 percent) and a high degree of accuracy in terms of tolerance (mean ± standard deviation=0.163 ± 0.029). Based on the results of this study, further investigation of CAD CAM technology for the purpose of assessment and education of dental students is recommended.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cad cam
12
cam technology
8
computer aided
8
dental students
8
dots diagonal"
8
reliability cad
4
technology assessing
4
assessing crown
4
crown preparations
4
preparations preclinical
4

Similar Publications

Background: The minimally invasive Nuss procedure has emerged as the standard of care for correction of pectus excavatum. The site of chest wall insertion and bar shape are currently contoured on the basis of the surgeon's judgment. To optimize and individualize Nuss bar configuration, we aimed to create a virtual surgical planning workflow and 3-dimensional (3D) printed Nuss bar molds customized to each patient's defect.

View Article and Find Full Text PDF

Background: Adolescent idiopathic scoliosis, a complex three-dimensional spine deformity, presents a formidable challenge for orthopedic residents in understanding its anatomy and surgical strategies. The aim of this study is to investigate the impact of three-dimensional printing (3DP) models in enhancing the comprehension of adolescent idiopathic scoliosis among orthopedic residents.

Methods: Forty orthopedic residents were randomly divided into two groups, the first group received lectures that were augmented with 3DP models illustrating five cases of adolescent idiopathic scoliosis, along with corresponding X-ray and CT images.

View Article and Find Full Text PDF

Aneurysm dome and vessel pressure measurements with coiling, stent assisted coiling and flow diversion.

Acta Neurochir (Wien)

January 2025

Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.

Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.

View Article and Find Full Text PDF

The preoperative fabrication of well-contoured, computer-aided design and computer-aided manufacturing (CAD-CAM), custom healing abutments is essential for guiding soft tissue healing and saving chairside time. This dental technique involves a fully digital workflow to fabricate a CAD-CAM custom healing abutment that relies on preoperative digital implant planning. The healing abutment is designed with an optimal emergence profile that can predictably direct the anatomy of the peri-implant mucosa.

View Article and Find Full Text PDF

Case: The effective reconstruction and functional restoration of the shoulder joint after surgical treatment of shoulder girdle tumors, especially those involving resection of the glenoid, poses significant challenges. Reconstruction methods include allograft reconstruction and shoulder prosthesis. In this report, we present 2 cases of scapulectomy for tumors involving the glenoid, followed by shoulder reconstruction using custom-designed reverse shoulder prostheses that are partially fixed to the clavicle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!