Zirconia femoral heads were introduced for total hip arthroplasty (THA) with the expectation of lower polyethylene (PE) wear and better clinical results. Because several studies reported poor survivorship of yttria-stabilized zirconia-PE THA, we investigated a new-generation yttria-stabilized zirconia head (diameter, 26 mm) manufactured by NGK Spark Plug. We retrieved six zirconia heads at revision THA after they had been in place for a mean of 8.6 years and measured their surface roughness and mean monoclinic content. Although their mean monoclinic content was higher than that of the unused head, surface roughness in the implanted heads was as low as that of the unused head, indicating that wear reduction may be possible with the selection of a suitable zirconia femoral head.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00590-013-1397-5 | DOI Listing |
J Dent Res
January 2025
Center for MicroElectroMechanical Systems, Universidade do Minho, Guimarães, Portugal.
In the present in vitro study, we evaluated the adhesion of an injectable platelet-rich fibrin (i-PRF) to laser-textured zirconia surfaces and their resultant friction behavior against bone tissue. Three types of zirconia surfaces were compared regarding the i-PRF coating effects: 1) grit blasted with 250-μm spherical alumina particles and acid etched with 20% hydrofluoric acid (ZLA), 2) laser textured with a random (RD) surface pattern, or 3) laser textured with a designed pattern based on 16 lines and 8 passages (L16N8). The coefficient of friction (COF) of the specimens was assessed on a reciprocating sliding pin-on-plate tribometer at 1-N normal load, 1 Hz, and a 2-mm stroke length.
View Article and Find Full Text PDFInt J Nanomedicine
December 2024
School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
September 2024
Department of Orthopaedic Surgery, the Central Hospital of Wuhan, Tongji Medical College of Huazhong University of Science & Technology, Wuhan Hubei, 430010, P. R. China.
Objective: To analyze the occurrence of osteolysis in total hip arthroplasty (THA) with highly cross-linked polyethylene prosthesis during a follow-up of more than 15 years.
Methods: The clinical data of 84 patients (105 hips) treated with THA in the Affiliated Hospital of Kanazawa Medical University in Japan between June 2000 and April 2004 and met the selection criteria was retrospectively analyzed. There were 7 males and 77 females, aged from 41 to 75 years, with an average of 56.
Orthop Traumatol Surg Res
December 2024
Univ Jean Monnet, INSERM, Mines Saint-Étienne, U1059 SAINBIOSE, 42270 Saint-Étienne, France; Mines Saint-Etienne, INSERM, U1059 SAINBIOSE, Univ Jean Monnet, 42270 Saint Etienne, France.
Background: Y-TZP zirconia heads were recalled by the Food and Drug Administration (FDA) in 2001 and zirconia alone was no longer used in orthopedics. Tunnel furnace sintering was suspected of producing defects responsible for early material failure. As Zirconia Toughened Alumina (ZTA) matrices are widely used as bearing material and contain zirconia grains, there remains a need to better understand the in vivo ageing process of zirconia and its clinical implications when the material is produced by batch furnace sintering, the validated sintering process.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
October 2024
Research Laboratory for Biomechanics and Implant Technology, Department of Orthopedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany.
Multifunctional materials have been described to meet the diverse requirements of implant materials for femoral components of uncemented total knee replacements. These materials aim to combine the high wear and corrosion resistance of oxide ceramics at the joint surfaces with the osteogenic potential of titanium alloys at the bone-implant interface. Our objective was to evaluate the biomechanical performance of hybrid material-based femoral components regarding mechanical stress within the implant during cementless implantation and stress shielding (evaluated by strain energy density) of the periprosthetic bone during two-legged squat motion using finite element modeling.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!