Aim: To present the segmented photon beams technique (SPBT) for irradiation of postmastectomy patients.

Background: In majority of techniques for irradiation of posmastectomy patients, a few adjacent photon or electron beams were usually implemented in order to encompass different parts of the target. In the presented SPBT technique, the radiotherapy plan consists of 6 isocentric photon beams and the area CTV includes both the chest wall and the supraclavicular area. This makes it possible to provide a uniform dose to the CTV with no hot and cold points and enables the determination of doses for the entire volume of critical organs.

Methods And Material: The treatment forward-IMRT plan comprises six isocentric 4 and 15 MV photon beams. Modulation of the dose distribution for each field was obtained by applying three segments on average. The total dose of 45 Gy was administered in 20 fractions. Dose distributions in target volume and organs at risk were evaluated for 70 randomly chosen patients.

Results: On average, 94.8% of the CTV volume received doses within 95-107% of the prescribed dose. The average volume of the heart receiving a dose of 30 Gy and lager was 2% for patients with left breast cancer. The average dose to the lung on the irradiation side was always lower than 15.5 Gy and the average V20 Gy was below 35.5%.

Conclusions: The SPBT complies with requirements for high dose homogeneity within the target volume and satisfactory level of sparing of organs at risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3863164PMC
http://dx.doi.org/10.1016/j.rpor.2012.01.008DOI Listing

Publication Analysis

Top Keywords

photon beams
16
segmented photon
8
beams technique
8
irradiation postmastectomy
8
dose
8
target volume
8
organs risk
8
beams
5
volume
5
average
5

Similar Publications

Vortex beams are currently drawing a great deal of interest, from fundamental research to several promising applications. While their generation in bulky optical devices limits their use in integrated complex systems, metasurfaces have recently proven successful in creating optical vortices, especially in the linear regime. In the nonlinear domain, of strategic importance for the future of classical and quantum information, to date orbital angular momentum has only been created in qualitative ways, without discussing discrepancies between design and experimental results.

View Article and Find Full Text PDF

When observing chip-to-free-space light beams from silicon photonics (SiPh) to free space, manual adjustment of camera lens is often required to obtain a focused image of the light beams. In this Letter, we demonstrated an auto-focusing system based on the you-only-look-once (YOLO) model. The trained YOLO model exhibits high classification accuracy of 99.

View Article and Find Full Text PDF

This study aimed to evaluate the dosimetric and clinical outcomes of flattening filter (FF) versus flattening filter-free (FFF) beams in head and neck cancer (HNC) patients treated with volumetric modulated arc therapy (VMAT). Twenty-four patients with 70/59.4/54 Gy dose prescribed in 33 fractions with simultaneous integrated boost treatment were retrospectively analyzed to compare treatment delivery efficiency, target coverage, sparing of organs at risk (OARs), and remaining volume at risk (RVR) in two HNC groups (nasopharyngeal and oropharyngeal).

View Article and Find Full Text PDF

This study assesses radiation doses in multi-slice computed tomography (CT) using epoxy resin and PMMA phantoms, focusing on the relationship between TAR (tissue air ratio) and kilovoltage peak (kVp). The research was conducted using a Hitachi Supria 16-slice CT scanner. An epoxy resin phantom was fabricated from commercially available materials, to simulate human tissue.

View Article and Find Full Text PDF

A Theoretical Study on Crossings Among Electronically Excited States and Laser Cooling of Group VIA (S, Se, and Te) Hydrides.

J Comput Chem

January 2025

Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China.

Various electronically excited states and the feasibility of direct laser cooling of SH, SeH, and TeH are investigated using the highly accurate ab initio and dynamical methods. For the detailed calculations of the seven low-lying Λ-S states of SH, we utilized the internally contracted multireference configuration interaction approach, considering the spin-orbit coupling (SOC) effects. Our calculated spectroscopic constants are in very good agreement with the available experimental results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!