Purpose: Kinetic analysis using dynamic contrast enhanced MRI to assess neovascularization of carotid plaque requires images with high spatial and temporal resolution. This work demonstrates a new three-dimensional (3D) dynamic contrast enhanced imaging sequence, which directly measures the arterial input function with high temporal resolution yet maintains the high spatial resolution required to identify areas of increased adventitial neovascularity.

Theory And Methods: The sequence consists of multiple rapid acquisitions of a saturation prepared dynamic 3D gradient recalled echo (GRE) sequence temporally interleaved with multiple acquisitions of a 2D slice. The saturation recovery time was adjusted to maintain signal linearity with the very different contrast agent concentrations in the 2D slice and 3D volume. The K(trans) maps were obtained from the 3D dynamic contrast measurements while the 2D slice was used to obtain the arterial input function. Calibration and dynamic studies are presented.

Results: For contrast agent concentrations up to 5 mM, a saturation recovery time for the 2D slice of 20 ms resulted in less than a 10% deviation from the desired linear response of signal intensity with contrast agent concentration. The corresponding saturation recovery time of 83 ms for the 3D volume maintained less than a 10% deviation from the linear response up to contrast agent concentrations of 2 mM while a contrast agent concentration of 5 mM had almost a 30% deviation. There was a significant improvement in signal attenuation (9 ± 3% versus 23 ± 5% at 40 cm/s) when flow compensation was added to the slice select gradients. For patient studies, volume transfer and plasma fraction maps were calculated with data from the proposed sequence.

Conclusion: This work demonstrated a novel sequence for 3D dynamic contrast enhanced imaging with a simultaneously acquired 2D slice that directly measures the arterial input function with high temporal resolution. Acquisition parameters can be adjusted to accommodate the full range of contrast agent concentration values to be encountered and the kinetic parameters obtained were consistent with expected values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4069205PMC
http://dx.doi.org/10.1002/mrm.24993DOI Listing

Publication Analysis

Top Keywords

contrast agent
24
dynamic contrast
20
contrast enhanced
16
arterial input
16
input function
16
enhanced imaging
12
temporal resolution
12
saturation recovery
12
recovery time
12
agent concentrations
12

Similar Publications

The use of rare earth elements has increased in recent years, leading to a rise in environmental concentrations. Despite the growth in number of studies regarding toxicity, knowledge gaps remain. For Daphnia magna, standardized test methods involve exposure periods of either 48 h or 21 days to assess toxicological effects.

View Article and Find Full Text PDF

Adolescence is a developmental period of relative volatility, where the individual experiences significant changes to their physical and social environment. The ability to adapt to the volatility of one's surroundings is an important cognitive ability, particularly while foraging, a near-ubiquitous behaviour across the animal kingdom. As adolescents experience more volatility in their surroundings, we predicted that this age group would be more adept than adults at using exploration to adjust to volatility.

View Article and Find Full Text PDF

Background: People share health-related experiences and treatments, such as for insomnia, in digital communities. Natural language processing tools can be leveraged to understand the terms used in digital spaces to discuss insomnia and insomnia treatments.

Objective: The aim of this study is to summarize and chart trends of insomnia treatment terms on a digital insomnia message board.

View Article and Find Full Text PDF

Pulsed Ultrasound-Mediated Drug Delivery Enhancement Through Human Sclera.

Transl Vis Sci Technol

January 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.

Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate whether the iodine contrast in blood and solid organs differs between men and women and to evaluate the effect of BMI, height, weight, and blood volume (BV) on sex-specific contrast in staging CT.

Materials And Methods: Patients receiving a venous-phase thoracoabdominal Photon-Counting Detector CT (PCD-CT) scan with 100- or 120-mL CM between 08/2021 and 01/2022 were retrospectively included in this single-center study. Image analysis was performed by measuring iodine contrast in the liver, portal vein, spleen, left atrium, left ventricle, pulmonary trunk, ascending and descending aorta on spectral PCD-CT datasets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!