The Chinese spallation neutron source (CSNS) is a high-performance pulsed neutron source, having 20 neutron beamlines for neutron scattering instruments. The shielding design of these beamlines is usually needed for Monte Carlo (MC) calculation, and the use of variance reduction methods is critical to carrying out an efficient, reliable MC shielding calculation. This paper discusses the source biasing method based on actual source term and geometry model of a CSNS neutron beamline. Dose distribution throughout the geometry model was calculated with the FLUKA MC code. Full analogue calculation and biased calculation were compared, and it was validated that the source biasing method can effectively promote the calculation efficiency.