Objectives: The aim was to investigate the image quality of dual-energy computed-tomography (DECT) compared to single-energy images at 80 kV and 140 kV in oral tumors.
Materials And Methods: Forty patients underwent a contrast-enhanced DECT scan on a definition flash-CT. Four reconstructions (80 kV, 140 kV, mixed (M), and optimum-contrast (OC)) were assessed by four blinded readers for subjective image quality (10-point scale/10=best). For objective quality assessment, linear attenuation measurements (line density profiles (LDP)) were positioned at the tumor margin, and the difference between minimum and maximum was calculated. Signal-to-noise ratios (SNR) were measured in the tongue.
Results: The mean image quality for all readers was 5.1±0.3, 8.4±0.3, 8.1±0.2, and 8.3±0.2 for the 140 kV, 80 kV, M, and OC, respectively (P<001 between 140 kV and all others). The mean difference between the minimum and maximum within the LDP was 139.4±59.0, 65.7±29.5, 105.1±46.5, and 118.7±59.4 for the 80 kV, 140 kV, M, and OC, respectively (P<001). The SNR for the tongue was 3.8±2.1, 3.8±2.1, 4.2±2.4, and 4.1±2.3 for the 80 kV, 140 kV, M, and OC, respectively.
Discussion: DECT of oral tumors offers high image quality, with subjectively rated image quality and attenuation contrast at the tumor margin similar to that of 80 kV; DECT, however, provides a significantly higher SNR compared to 80 kV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oraloncology.2013.12.001 | DOI Listing |
ACS Nano
January 2025
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
Optical metasurfaces, arrays of nanostructures engineered to manipulate light, have emerged as a transformative technology in both research and industry due to their compact design and exceptional light control capabilities. Their strong light-matter interactions enable precise wavefront modulation, polarization control, and significant near-field enhancements. These unique properties have recently driven their application in biomedical fields.
View Article and Find Full Text PDFACS Biomater Sci Eng
January 2025
Department of Gastrointestinal Surgery, Affiliated Hospital of Nantong University, Medical School of Nantong University, Nantong 226001, China.
Perianal fistulas (PAFs) are a severe complication of Crohn's disease that significantly impact patient prognosis and quality of life. While stem-cell-based strategies have been widely applied for PAF treatment, their efficacy remains limited. Our study introduces an injectable, temperature-controlled decellularized adipose tissue-alginate hydrogel loaded with dental pulp mesenchymal stem cells (DPMSCs) for in vivo fistula treatment.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
State Key Laboratory of Advanced Drug Delivery and Release Systems, School of Pharmaceutical Sciences, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, Shandong, 250117, P. R. China.
Mitochondrial quality control is paramount for cellular development, with mitochondrial electron flow (Mito-EF) playing a central role in maintaining mitochondrial homeostasis. However, unlike visible protein entities, which can be monitored through chemical biotechnology, regulating mitochondrial quality control by invisible entities such as Mito-EF has remained elusive. Here, a Mito-EF tracker (Mito-EFT) with a four-pronged probe design is presented to elucidate the dynamic mechanisms of Mito-EF's involvement in mitochondrial quality control.
View Article and Find Full Text PDFActa Orthop
January 2025
Helsinki New Children's Hospital, Helsinki University Hospital, Helsinki, Finland.
Spondylolysis is defined as a defect or elongation in the pars interarticularis of the lumbar spine, either unilateral or bilateral. Growing children with bilateral spondylolysis may develop spondylolisthesis, i.e.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (N.M., A.I., A.L., L.B., T.D., D. Kravchenko, D. Kuetting, C.C.P., J.A.L.); Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany (N.M., A.I., L.B., D. Kravchenko, D. Kuetting, J.A.L.); Philips Healthcare, Hamburg, Germany (C.K.); Philips Medical Systems, Eindhoven, the Netherlands (A.H.-M.); and Department of Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany (C.Y.).
Objectives: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2S and DWIS) and with BG (T2BG and DWIBG).
Materials And Methods: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions.