Objectives: The aim of this study was to investigate the adhesive stability over time of a multi-mode one-step adhesive applied using different bonding techniques on human coronal dentine. The hypotheses tested were that microtensile bond strength (μTBS), interfacial nanoleakage expression and matrix metalloproteinases (MMPs) activation are not affected by the adhesive application mode (following the use of self-etch technique or with the etch-and-rinse technique on dry or wet dentine) or by ageing for 24h, 6 months and 1year in artificial saliva.
Methods: Human molars were cut to expose middle/deep dentine and assigned to one of the following bonding systems (N=15): (1) Scotchbond Universal (3M ESPE) self-etch mode, (2) Scotchbond Universal etch-and-rinse technique on wet dentine, (3) Scotchbond Universal etch-and-rinse technique on dry dentine, and (4) Prime&Bond NT (Dentsply De Trey) etch-and-rinse technique on wet dentine (control). Specimens were processed for μTBS test in accordance with the non-trimming technique and stressed to failure after 24h, 6 months or 1 year. Additional specimens were processed and examined to assay interfacial nanoleakage and MMP expression.
Results: At baseline, no differences between groups were found. After 1 year of storage, Scotchbond Universal applied in the self-etch mode and Prime&Bond NT showed higher μTBS compared to the other groups. The lowest nanoleakage expression was found for Scotchbond Universal applied in the self-etch mode, both at baseline and after storage. MMPs activation was found after application of each tested adhesive.
Conclusions: The results of this study support the use of the self-etch approach for bonding the tested multi-mode adhesive system to dentine due to improved stability over time.
Clinical Significance: Improved bonding effectiveness of the tested universal adhesive system on dentine may be obtained if the adhesive is applied with the self-etch approach.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jdent.2013.12.008 | DOI Listing |
Oper Dent
January 2025
*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.
This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.
View Article and Find Full Text PDFJ Dent
December 2024
Department of Conservative Dentistry and Periodontology and Center of Dental Traumatology, University Hospital of Würzburg, Pleicherwall 2, 97070 Würzburg, Germany. Electronic address:
Objectives: The aim of this in-vitro study was to investigate the masking efficacy of adhesively sealed enamel cracks with resin infiltration compared with the use of a universal adhesive.
Methods: Enamel cracks were induced on the labial surfaces of bovine teeth using a pendulum impact tester. Specimens were treated adhesively by resin infiltration with ICON (DMG) or Scotchbond Universal Plus (3M).
Clin Oral Investig
December 2024
Department of Primary Dental Care, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA.
Objective: This randomized controlled trial compared the 1-year clinical efficacy of Scotchbond Universal Adhesive Plus (SBU+) with that of its predecessor Scotchbond Universal Adhesive (SBU) to restore Class I and Class II preparations using the self-etch strategy in adult patients.
Materials And Methods: Fifty-one subjects participated in this study. Two posterior teeth in each subject were randomized to a restoration with SBU+ or to a restoration with SBU (control) using the self-etch strategy.
Braz Dent J
December 2024
Department of Restorative Dentistry. Piracicaba Dental School, University of Campinas, Brazil.
This study investigated the effects of nonthermal atmospheric pressure plasma (NAPP) application and dentin rehydration with water (REHY) on bond strength (BS) of adhesives. Three etch-and-rinse adhesives were tested: Scotchbond Multi-Purpose (SBM / water-based primer + adhesive resin), Gluma Bond Universal (GBU / single-bottle containing acetone as organic solvent) and Prime&Bond Universal (PBU / single-bottle containing propanol as organic solvent). Adhesives were applied: 1- to phosphoric acid-etched dentin (Control), 2- after NAPP application for 45 seconds to etched dentin or 3- after REHY with water (10 seconds) of plasma-treated etched dentin.
View Article and Find Full Text PDFJ Dent
December 2024
Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University. José Bonifácio St. 1193, Araçatuba, SP, Brazil. Electronic address:
Objective: To evaluate the retention rate and other clinical criteria of four different restorative techniques for non-carious cervical lesions (NCCLs) after 4 years.
Methods: This is a prospective, randomized, double-blind, and split-mouth study evaluating four different adhesion strategies in non-carious cervical lesion restorations: adhesive restorative system (Scotchbond Universal Adhesive/Filtek Z350XT) without (SBU) and with selective enamel acid-etching (E-SBU), resin-modified glass-ionomer cements (Vitremer; RMGIC), and ethylenediaminetetraacetic as acid pretreatment (E-RMGIC). In total, 200 restorations were placed in 50 patients.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!