A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of bronchoalveolar lavage fluid obtained by manual aspiration with a handheld syringe with that obtained by automated suction pump aspiration from healthy dogs. | LitMetric

Objective: To compare bronchoalveolar lavage (BAL) fluid obtained by manual aspiration (MA) with a handheld syringe with that obtained by suction pump aspiration (SPA) in healthy dogs.

Animals: 13 adult Beagles.

Procedures: Each dog was anesthetized and bronchoscopic BAL was performed. The MA technique was accomplished with a 35-mL syringe attached to the bronchoscope biopsy channel. The SPA technique was achieved with negative pressure (5 kPa) applied to the bronchoscope suction valve with a disposable suction trap. Both aspiration techniques were performed in each dog in randomized order on opposite caudal lung lobes. Two 1 mL/kg aliquots of warm saline (0.9% NaCl) solution were infused per site. For each BAL fluid sample, the percentage of retrieved fluid was calculated, the total nucleated cell count (TNCC) and differential cell count were determined, and semiquantitative assessment of slide quality was performed. Comparisons were made between MA and SPA techniques for each outcome.

Results: 1 dog was removed from the study because of illness. The mean percentage of fluid retrieved (mean difference, 23%) and median TNCC (median distribution of differences, 100 cells/μL) for samples obtained by SPA were significantly greater than those for samples obtained by MA.

Conclusions And Clinical Relevance: In healthy dogs, BAL by SPA resulted in a significantly higher percentage of fluid retrieval and samples with a higher TNCC than did MA. Further evaluation of aspiration techniques in dogs with respiratory tract disease is required to assess whether SPA improves the diagnostic yield of BAL samples.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.75.1.85DOI Listing

Publication Analysis

Top Keywords

bronchoalveolar lavage
8
fluid manual
8
manual aspiration
8
aspiration handheld
8
handheld syringe
8
suction pump
8
pump aspiration
8
healthy dogs
8
bal fluid
8
aspiration techniques
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!