In this study, which investigates the relationship between the levels of stereopsis with eye and hand dominance or interpupillary distance, 120 healthy young volunteers were investigated. Eye dominance was determined by modified Miles technique following a complete eye examination. Handedness was assessed with the Edinburgh handedness inventory. Interpupillary distance was measured with millimetric ruler. Stereoacuity was measured in both contour (Titmus test) and random dot (TNO test) stereograms. The stereopsis scores were evaluated in terms of hand or eye dominance. The correlation between stereopsis score and interpupillary distance was assessed. Main outcome measures were stereopsis scores according to hand and eye dominance. As a result, right- and left-handed individuals showed no differences in terms of stereopsis. No differences were found in stereopsis scores between right- and left-eye dominant people. There was a correlation between interpupillary distance and the depth of stereopsis (r = -0.248, P < 0.05). Contrary to the expectation, the left and right dominant individuals did not differ in levels of stereopsis. Interpupillary distance has a positive effect on stereopsis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3863493 | PMC |
http://dx.doi.org/10.1155/2013/485059 | DOI Listing |
Behav Res Methods
January 2025
CIMeC, Center for Mind/Brain Sciences, The University of Trento, Trento, Italy.
Sighting dominance is an important behavioral property which has been difficult to measure quantitatively with high precision. We developed a measurement method that is grounded in a two-camera model that satisfies these aims. Using a simple alignment task, this method quantifies sighting ocular dominance during binocular viewing, identifying each eye's relative contribution to binocular vision.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Department of Ophthalmology, Maulana Azad Medical College, New Delhi, India.
Clin Optom (Auckl)
December 2024
School of Optometry and Vision Science, Daegu Catholic University, Gyeongsan-si, Republic of Korea.
Purpose: The use of mobile phone applications (apps) in the health sector, including in eye care, is increasing. This study aimed to compare interpupillary distance (IPD) measurements using common clinical techniques (pupillometer, PD ruler, and autorefractor), which are contact procedures, with measurements from a non-contact mobile phone application.
Methods: Forty participants were recruited (mean age 25.
Cutan Ocul Toxicol
December 2024
Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!