Introduction: With an expanding population of patients requiring ventricular assist devices, it is inevitable that these patients will require noncardiac surgery. Ventricular assist devices provide mechanical support for a failing heart either as a bridge to transplant or now as a long-term support if transplant is not available, so-called destination therapy. These devices can add significant technical challenges to abdominal surgery, in that the power supply and drivelines crossing the abdomen can potentially be damaged. The use of preoperative or intraoperative imaging may aid in locating these devices and increase patient safety.

Materials And Methods: We describe a laparoscopic cholecystectomy in two patients supported with HeartMate(®) II (Thoratec Corp., Pleasanton, CA) left ventricular assist devices. Our use of fluoroscopic guidance in port placement is also described. A literature review was performed to assess the frequency of laparoscopic procedures performed on patients with similar ventricular assist devices and of complications associated with the device and other comorbidities.

Results: Laparoscopic cholecystectomy was performed without significant intraoperative hemodynamic changes. The use of imaging, such as fluoroscopy, can identify the location of the ventricular assist device and its associated drive wires to assure they are not damaged intraoperatively.

Conclusions: Laparoscopic cholecystectomy can be performed safely on patients with ventricular assist devices. Complications due to damage to the device can be avoided with the assistance of fluoroscopy to identify the implanted abdominal portions of the ventricular assist device. Each laparoscopic procedure performed on these patients presents the surgeon with unique obstacles in which careful operative planning and intraoperative monitoring are essential.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lap.2013.0460DOI Listing

Publication Analysis

Top Keywords

ventricular assist
32
assist devices
24
laparoscopic cholecystectomy
16
cholecystectomy patients
8
ventricular
8
left ventricular
8
assist
8
devices
8
performed patients
8
patients ventricular
8

Similar Publications

We report a case of a patient with dilated cardiomyopathy who experienced recurrent ventricular tachycardia (VT) and multiple defibrillations following CRT-D implantation. Due to worsening cardiac function, the patient required surgical implantation of a left ventricular assist device (LVAD) as a bridge to heart transplantation. During the procedure, we used the Ensite three-dimensional mapping system to perform activation and substrate mapping of the VT targets, followed by endocardial and epicardial cryoballoon ablation of clinical VT.

View Article and Find Full Text PDF

Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.

Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.

View Article and Find Full Text PDF

An automatic and real-time echocardiography quality scoring system based on deep learning to improve reproducible assessment of left ventricular ejection fraction.

Quant Imaging Med Surg

January 2025

Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.

Background: Echocardiography can conveniently, rapidly, and economically evaluate the structure and function of the heart, and has important value in the diagnosis and evaluation of cardiovascular diseases (CVDs). However, echocardiography still exhibits significant variability in image acquisition and diagnosis, with a heavy dependency on the operator's experience. Image quality affects disease diagnosis in the later stage, and even image quality assessment still has variability in human evaluation.

View Article and Find Full Text PDF

To explore techniques, advantages and disadvantages of 3D Slicer reconstruction and 3D printing localization technology combined with transcranial neuroendoscopy in ventriculoperitoneal shunt surgery. Retrospective analysis of clinical data of patients with hydrocephalus treated by ventriculoperitoneal shunt surgery using 3D Slicer reconstruction and 3D printing positioning technology combined with transcranial neuroendoscopy in our hospital from October 2021 to March 2023. A total of 33 patients with complete data were collected, including 19 males and 14 females, aged 10-81 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!