Introduction: Accurate determination of donor kidney function has important long-term implications for both donor health and recipient outcome. Many centers use 24 hour urinary creatinine clearance or creatinine-based GFR estimations to assess kidney function but their performance when compared with GFR measurements by isotope clearance remains inconclusive. We assessed the performance of creatinine based equations against DTPA GFR for evaluating Nepalese kidney donors.
Methods: All kidney donors who had undergone both DTPA GFR estimation and 24 hour urine CrCl were included. The performance of the urine-CrCl, CG-CrCl, modified MDRD GFR against DTPA GFR was evaluated by analyzing global bias, precision (R2),Pearson correlation and accuracy percentage within 30% and 15%. The sensitivity and specificity of each predictive equation in selecting donor with GFR of ≥80 mL/min/1.73 m2 was also calculated.
Results: Of 51 donors analysed, only 18 (35.29%) were male. The mean measured GFR was 102.752±16.71 mL/min/1.73 m2. Of all prediction equations, urine-CrCL has most precision (R2=0.207) with the highest pearson correlation (0.455) and highest accuracy percentage within 30% and 15%. However, predictive performance was poor for all the equations. The urine CrCl had highest sensitivity of 100% for detecting donor with measured GFR>80 mL/min/1.73 m2 with positive predictive value of 92.1%.
Conclusions: The performance of all equations was disappointing and even the best performing equation urine-CrCl was suboptimal for donor selection. So considering the potential risk of living kidney donation, other more accurate methods of GFR estimation should be used.
Download full-text PDF |
Source |
---|
BMC Nephrol
January 2025
Department of Urology, Nara Medical University, 840 Shijo-cho, Kashihara, Nara, 634-8522, Japan.
Background: The existing criteria for living kidney donors (LKDs)in Japan are controversial. We evaluated the roles of computed tomography volumetry (CTV) and 99 m Tc-diethylenetriamine penta-acetic acid (DTPA) scintigraphy in assessing preoperative and postoperative renal function and predicting early recovery of residual renal function.
Methods: We retrospectively reviewed the medical charts of 175 consecutive LKDs who underwent donor nephrectomy (DN) at our institution between 2006 and 2022.
Front Physiol
December 2024
Department of Urology, School of Rehabilitation, China Rehabilitation Research Center, Beijing Bo'ai Hospital, Capital Medical University, Beijing, China.
Purpose: Glomerular filtration rate (GFR) measured by dynamic renal scintigraphy (Gates method) is used in this study as the standard to investigate the applicability of two creatinine (Cr)-based GFR estimation equations in Chinese patients of different genders, age groups, and GFR stages diagnosed with neurogenic bladder (NB).
Methods: GFR values were measured using Tc-DTPA renal dynamic imaging, the new serum creatinine (Cr)-based chronic kidney disease epidemiology collaborative group (CKD-EPI) equation, and the equation for the estimated GFR of CKD patients in China, which were designated as sGFR, EPI-GFR, and cGFR, respectively. Pearson's correlation and linear regression were used to compare the differences, absolute differences, precision, and accuracies of the results of the two equations with sGFR to determine the formula offering better performance for the assessment of patients with NB.
Quant Imaging Med Surg
December 2024
Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Background: En bloc kidney transplantation (EBKT) involves transplantation of two kidneys, the aorta, and inferior vena cava from a deceased pediatric donor into an adult recipient. Recent articles have shown that EBKT is associated with excellent long-term allograft performance and patient survival. Developmental differences exist between the two transplanted kidneys after EBKT, and it is crucial to assess split renal function.
View Article and Find Full Text PDFDiagnostics (Basel)
November 2024
Department of Radiological Sciences, College of Applied Medical Sciences, Najran University, Najran 61441, Saudi Arabia.
: Cisplatin is a potent agent commonly used to treat cancer, but its effects pose a significant risk to renal function. Therefore, the present study aimed to evaluate the impact of cisplatin on renal function as measured by glomerular filtration rate (GFR) using diethyltriamine-penta-acetic acid (DTPA) renal scintigraphy. : Extensive literature searches were performed using PRISMA guidelines that investigated cisplatin-induced renal failure by measuring GFR with DTPA.
View Article and Find Full Text PDFEJNMMI Phys
October 2024
Department of Health Science and Technology, Graduate School of Convergence Science and Technology, Seoul National University, Gwanggyo-ro 145, Yeongtong-gu, Suwon, Gyeonggi-do, 16229, Republic of Korea.
Background: Accurate attenuation correction (AC) is vital in nuclear medicine, particularly for quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) imaging. This study aimed to establish a CT-free quantification technology in kidney SPECT imaging using deep learning to generate synthetic attenuation maps (μ-maps) from SPECT data, thereby reducing radiation exposure and eliminating the need for CT scans.
Results: A dataset of 1000 Tc-99m DTPA SPECT/CT scans was analyzed for training (n = 800), validation (n = 100), and testing (n = 100) using a modified 3D U-Net for deep learning.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!