  • - The study aimed to meta-analyze the diagnostic accuracy of serum glypican-3 (GPC-3) for diagnosing hepatocellular carcinoma (HCC), given inconsistent results from prior research.
  • - Twelve studies involving 898 HCC patients and 835 non-HCC patients showed that GPC-3 has moderate sensitivity (53%) and relatively better specificity (77%) for HCC diagnosis, with an area under the curve (AUC) of 0.82.
  • - The authors noted design flaws in the studies reviewed, such as verification bias and poor exclusion criteria, suggesting that results should be approached with caution, and called for more robust research to confirm GPC-3's diagnostic value.

Article Abstract

Objective: Many individual studies have evaluated the diagnostic efficiency of serum glypican-3 (GPC-3) for diagnosing hepatocellular carcinoma (HCC), but the results have been inconsistent. The aim of present study was to meta-analyze the overall diagnostic accuracy of serum GPC-3 for diagnosing HCC.

Design And Methods: English language studies which evaluated the diagnostic performance of GPC-3 and published before March 22, 2013 were retrieved. The quality of the studies was assessed by revised QUADAS tools. The performance characteristics were pooled and determined by random-effects models.

Results: Twelve studies with a total of 898 HCC patients and 835 non-HCC patients were included. For the studies in which the majority of reference participants had HBV or HCV infections, the overall diagnostic sensitivity and specificity were 0.53 (95% CI: 0.49-0.57) and 0.77 (95% CI: 0.74-0.81), respectively. The area under summary receiver operating characteristic (sROC) curves (AUC) was 0.82. The major design deficiencies of included studies were differential verification bias, and a lack of clear exclusion and inclusion criteria.

Conclusions: GPC-3 has moderate diagnostic accuracy for HCC. Due to the design limitations, results in published studies should be carefully interpreted. In addition, more well-designed studies with large sample sizes should be performed to rigorously evaluate the diagnostic value of the GPC-3.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiochem.2013.12.007DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
12
accuracy serum
8
serum glypican-3
8
hepatocellular carcinoma
8
studies
8
studies evaluated
8
evaluated diagnostic
8
gpc-3 diagnosing
8
included studies
8
diagnostic
7

Similar Publications

Purpose: This study aimed to investigate whether combining the analysis of different magnetic resonance imaging (MRI) signs enhances the diagnostic accuracy of lateral meniscus posterior root tears (LMPRTs) in patients with anterior cruciate ligament (ACL) injuries. We hypothesised that analysing the cleft, ghost and truncated triangle signs and lateral meniscus extrusion (LME) measurement together would improve the preoperative MRI-based diagnosis of LMPRTs.

Methods: This retrospective study used prospectively collected registry data from two academic centres, including patients undergoing primary or revision ACL reconstruction (ACLR) and LMPRT repair.

View Article and Find Full Text PDF

The rising incidence of pancreatic diseases, including acute and chronic pancreatitis and various pancreatic neoplasms, poses a significant global health challenge. Pancreatic ductal adenocarcinoma (PDAC) for example, has a high mortality rate due to late-stage diagnosis and its inaccessible location. Advances in imaging technologies, though improving diagnostic capabilities, still necessitate biopsy confirmation.

View Article and Find Full Text PDF

Previous studies demonstrated that sensorimotor training enhances interoceptive abilities. Athletes are highly engaged in performance-driven physical training and often incorporate-to varying degrees-sensorimotor training into their routines. In this study, we investigated the role of individual differences in interoception by comparing professional athletes of different performance levels and both sexes with recreational athletes and controls, applying a three-dimensional model of interoception.

View Article and Find Full Text PDF

Background And Aims: The performance of non-invasive liver tests (NITs) is known to vary across settings and subgroups. We systematically evaluated whether the performance of three NITs in detecting advanced fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD) varies with age, sex, body mass index (BMI), type 2 diabetes mellitus (T2DM) status or liver enzymes.

Methods: Data from 586 adult LITMUS Metacohort participants with histologically characterised MASLD were included.

View Article and Find Full Text PDF

Purpose: To compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.

Methods: A retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!