Predictors of 6-month poor clinical outcomes after transcatheter aortic valve implantation.

Arch Cardiovasc Dis

Inserm, U1099, Rennes, France; Université de Rennes 1, LTSI, Rennes, France; CHU de Rennes, Service de Cardiologie et Maladies Vasculaires, Rennes, France; Inserm, CIC-IT804, Rennes, France.

Published: January 2014

Background: Patient selection for transcatheter aortic valve implantation (TAVI) remains a major concern. Indeed, despite promising results, it is still unclear which patients are most and least likely to benefit from this procedure.

Aims: To identify predictors of 6-month poor clinical outcomes after TAVI.

Methods: Patients who were discharged from our institution with a transcatheter-implanted aortic valve were followed prospectively. Our population was divided into two groups ('good outcomes' and 'poor outcomes') according to occurrence of primary endpoint (composite of all-cause mortality, all stroke, hospitalizations for valve-related symptoms or worsening heart failure from discharge to 6 months or 6-month New York Heart Association functional class III or IV). Patient characteristics were studied to find predictors of poor outcomes.

Results: We included 163 patients (mean age, 79.9 ± 8.8 years; 90 men [55%]; mean logistic EuroSCORE, 18.4 ± 11.4%). The primary endpoint occurred in 49 patients (mean age, 83 ± 5 years; 31 men [63%]). By multivariable analysis, atrial fibrillation (odds ratio [OR] 3.94), systolic pulmonary artery pressure ≥60 mmHg (OR 7.56) and right ventricular dysfunction (OR 3.55) were independent predictors of poor outcomes, whereas baseline aortic regurgitation ≥2/4 (OR 0.07) demonstrated a protective effect.

Conclusion: Atrial fibrillation, severe baseline pulmonary hypertension and right ventricular dysfunction (i.e. variables suggesting a more evolved aortic stenosis) were predictors of 6-month poor outcomes. Conversely, baseline aortic regurgitation ≥2/4 showed a protective effect, which needs to be confirmed in future studies. Our study highlights the need for a specific 'TAVI risk score', which could lead to better patient selection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acvd.2013.10.005DOI Listing

Publication Analysis

Top Keywords

predictors 6-month
12
6-month poor
12
aortic valve
12
poor clinical
8
clinical outcomes
8
transcatheter aortic
8
valve implantation
8
patient selection
8
primary endpoint
8
predictors poor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!