Objective: Type I attachment site endoleaks are the most common cause for reintervention after thoracic endovascular aortic repair (TEVAR) and represent treatment failures. Deployment of endografts in segments of the aorta previously replaced with Dacron grafts may be associated with reduced type I endoleak due to mechanical stability and decreased potential for aortic remodeling. However, no study has rigorously examined endoleak rates in Dacron landing zones vs native aorta.

Methods: A retrospective analysis of a prospectively maintained database was performed to identify all patients undergoing TEVAR at a single referral institution between May 2002 and June 2012. Overall, 319 patients undergoing 345 procedures had at least one follow-up contrast-enhanced computed tomography scan to assess for postoperative type I endoleak. Attachment site landing zones were classified as native aorta, Dacron, or endograft if landed in a previously placed endograft. Patient characteristics and type I endoleak rates were compared among the three groups.

Results: Identified were 697 proximal or distal landing zones (native aorta, 599; Dacron, 79; and endograft, 19). Patients with at least one Dacron landing zone had higher rates of hypertension (P < .01), chronic obstructive pulmonary disease (P = .04), and prior aortic surgery (P < .01) and were more likely to have undergone complex hybrid repairs (P < .01). Cumulative type I endoleak rates were equivalent between the three types of landing zone (native aorta, 3.7%; Dacron, 2.5%; endograft, 0%; P = .44). Two type I endoleaks occurred with Dacron landing zones in the first tertile of TEVAR experience and with Dacron landing zone lengths of <2.5 cm. Evaluation of endoleak rates by tertile of experience demonstrated decreased type I endoleak rates in Dacron landing zones between the first and second/third tertiles of experience (13.3% vs 0%, P = .03) after a policy of using >4 to 5 cm (twice the device instructions for use) of Dacron overlap was initiated.

Conclusions: Endograft deployment within long-segment (landing zone length of >4-5 cm) Dacron represents a durable option for aortic repair and was associated with a 0% rate of type I endoleak. In cases of a borderline native aortic landing zone, a hybrid procedure to create an adequate Dacron landing zone may be warranted to decrease the risk of type I endoleak and treatment failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2013.10.086DOI Listing

Publication Analysis

Top Keywords

type endoleak
24
landing zone
24
landing zones
20
dacron landing
20
endoleak rates
16
native aorta
16
attachment site
12
dacron
12
aortic repair
12
landing
11

Similar Publications

Background: Current guidelines recommend preserving at least one of the bilateral pelvic flows in patients with aortoiliac aneurysms. The sandwich parallel graft, using commercially available devices, provides a viable option for patients who fall outside the instructions for use of iliac branch devices. However, gutter endoleak remains a significant challenge.

View Article and Find Full Text PDF

In situ Laser Fenestrations of Visceral Endografts (InLoVE) Midterm Outcomes From a Multicentre Study.

Eur J Vasc Endovasc Surg

December 2024

Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden.

Objective: Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting.

View Article and Find Full Text PDF

Background: The optimal treatment of complicated type B aortic dissection (cTBAD) involving arch anomalies remain unclear.

Methods: We consecutively enrolled patients with cTBAD involving arch anomalies who underwent endovascular repair using a single-branched stent graft (SBSG) at our medical center between January 2020 and January 2023. The demographics, clinical manifestation, operation detail, and follow-up outcomes of these patients were retrospectively collected and analyzed.

View Article and Find Full Text PDF

The purpose of this study is to evaluate the feasibility and clinical outcomes of vasa vasorum embolization for preventing continuous aneurysmal expansion after endovascular aneurysm repair (EVAR). We retrospectively reviewed the medical records of patients who underwent vasa vasorum embolization between August 2018 and May 2022. Vasa vasorum embolization was attempted in cases of continuous aneurysmal expansion after EVAR, where the vasa vasorum was identified through catheter angiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!