A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cardiac implantable electronic device reutilization: battery life of explanted devices at a tertiary care center. | LitMetric

Introduction: Prior studies have suggested that pacemaker reuse may be a reasonable alternative to provide device therapy in the low- and middle-income countries. We studied explant indications and remaining battery life of cardiac implantable electronic devices (CIEDs) at a tertiary medical center.

Methods And Results: We conducted a retrospective review of all CIEDs extracted at the University of Michigan between 2007 and 2011. Devices were considered reusable if battery longevity was ≥48 months or >75% battery life was remaining; there was no evidence of electrical malfunction, and they were not under advisory or recall. Eight hundred and one CIEDs were explanted: Medtronic (MDT [Medtronic Inc., Minneapolis, MN, USA]; 454), Boston Scientific (BS [Boston Scientific Corp., Natick, MA, USA])/Guidant (GDT; 255 [Guidant Corp., St. Paul, MN, USA]), St. Jude Medical (SJM; 73 [St. Paul, MN, USA]), and Biotronik (BTK; 15 [Biotronik GmBH, Berlin, Germany]). After eliminating devices explanted for elective replacement indicator (ERI, 541), 51.9% of pacemakers (41/79), 54.2% of implantable cardioverter-defibrillators (ICDs) (64/118), and 47.6% of cardiac resynchronization therapy and defibrillation (CRT-D) devices (30/63) had sufficient battery life and no evidence of electrical malfunction to be considered for reuse. A logistic regression analysis found that the indications for device removal independently predicted reusability: upgrade to an ICD (odds ratio [OR] 162.8, P < 0.001) or CRT-D (OR 63.8, P < 0.001), infection (OR 110.7, P < 0.001), heart transplantation or left ventricular assist device placement (OR 56.6, P < 0.001), and device removal at patient's request (OR 115.4, P < 0.001).

Conclusion: The majority of explanted CIEDs for reasons other than ERI have an adequate battery life and, if proven safe, may conceivably be reutilized for basic pacing in underserved nations where access to this life-saving therapy is limited.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.12321DOI Listing

Publication Analysis

Top Keywords

battery life
20
cardiac implantable
8
implantable electronic
8
evidence electrical
8
electrical malfunction
8
paul usa]
8
device removal
8
battery
6
device
5
life
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!