A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of tapered and cylindrical miniscrew stability. | LitMetric

A comparison of tapered and cylindrical miniscrew stability.

Eur J Orthod

*Department of Orthodontics, College of Dentistry and Institute of Craniofacial Deformity, Yonsei University, Seoul, and,

Published: October 2014

Objectives: This study compared the stability of tapered miniscrews with cylindrical miniscrews.

Materials/methods: One hundred and five tapered and 122 cylindrical self-drilling miniscrews were placed into the maxillary and mandibular buccal alveolar areas of 132 patients (43 males and 89 females). The insertion torque and removal torque were measured and Periotest values (PTVs) were recorded at implantation.

Results: The success rates of the tapered and cylindrical miniscrews examined were similar. In the maxilla, the insertion torque of the tapered miniscrews (8.3 Ncm) was significantly higher than that of the cylindrical miniscrews (6.3 Ncm) (P < 0.05). The PTVs of the tapered miniscrews were statistically significantly lower in the maxilla (P < 0.05). The removal torque values showed no significant difference between the tapered and cylindrical miniscrews in the upper and lower buccal areas (P > 0.05).

Conclusions: Tapered miniscrews had higher initial stability when compared to cylindrical miniscrews, whereas the clinical success rates and removal torques were similar between the two designs. The long-term stability is not directly affected by the miniscrew design.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejo/cjt092DOI Listing

Publication Analysis

Top Keywords

tapered miniscrews
16
cylindrical miniscrews
16
tapered cylindrical
12
miniscrews
9
insertion torque
8
removal torque
8
success rates
8
miniscrews ncm
8
cylindrical
7
tapered
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!