A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be 'achieved' in almost all cases? | LitMetric

AI Article Synopsis

  • Researchers aimed to optimize real-time assessment of pulmonary vein disconnection during cryoablation for atrial fibrillation, as previous methods showed only around 50% effectiveness.
  • In a study of 34 patients, they found that real-time monitoring was possible in 97.7% of pulmonary veins using a stepwise mapping approach and specific techniques such as repositioning the Achieve catheter and pacing maneuvers.
  • The study concluded that a systematic approach significantly enhances the ability to monitor pulmonary vein disconnection during the procedure, reducing the duration needed for effective assessment.

Article Abstract

Aim: Real-time assessment of pulmonary vein (PV) disconnection is possible using an inner circular mapping catheter during cryoablation of atrial fibrillation (AF). However, it has been recently demonstrated that such continuous monitoring may only be possible in <50% of PVs. We hypothesized that a stepwise mapping approach, including pacing manoeuvres, could optimize monitoring of real-time PV disconnection during ablation.

Methods And Results: Single-centre, prospective observational study (NCT01843465) including 34 consecutive eligible patients (128 PVs) undergoing a first procedure of cryoballoon ablation of AF using the Artic Front Advance(®) 28 mm catheter and a 20 mm diameter Achieve(®) catheter (AC) in all cases. Monitoring of real-time entrance block was possible, when AC was maintained in the standard position (distal to the tip of the Artic Front Advance(®) catheter) in 47 (36.7%) PVs. In an additional 63 cases (49.2%), such monitoring was possible after moving AC to a more proximal position and using different torqueing movements. Finally, using supplemental systematic pacing manoeuvres to test exit block, real-time assessment of PV disconnection was possible in 15 (11.7%) more PVs. Overall, real-time assessment of PV disconnection was possible in 97.7% of cases, after a mean duration of 48.6 ± 33.0 s.

Conclusion: Our results suggest that optimal use of the AC, with a systematic stepwise mapping approach, may dramatically improve the real-time monitoring of PV disconnection during AF cryoablation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eut366DOI Listing

Publication Analysis

Top Keywords

real-time assessment
8
assessment pulmonary
8
pulmonary vein
8
vein disconnection
8
cryoablation atrial
8
atrial fibrillation
8
disconnection cryoablation
4
fibrillation 'achieved'
4
'achieved' cases?
4
cases? aim
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!