A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical simulation of diffusion MRI signals using an adaptive time-stepping method. | LitMetric

Numerical simulation of diffusion MRI signals using an adaptive time-stepping method.

Phys Med Biol

INRIA Saclay-Equipe DEFI, CMAP, Ecole Polytechnique Route de Saclay, F-91128, Palaiseau Cedex, France. NeuroSpin, CEA Saclay Center 91191 Gif-sur-Yvette Cedex, France.

Published: January 2014

The effect on the MRI signal of water diffusion in biological tissues in the presence of applied magnetic field gradient pulses can be modelled by a multiple compartment Bloch-Torrey partial differential equation. We present a method for the numerical solution of this equation by coupling a standard Cartesian spatial discretization with an adaptive time discretization. The time discretization is done using the explicit Runge-Kutta-Chebyshev method, which is more efficient than the forward Euler time discretization for diffusive-type problems. We use this approach to simulate the diffusion MRI signal from the extra-cylindrical compartment in a tissue model of the brain gray matter consisting of cylindrical and spherical cells and illustrate the effect of cell membrane permeability.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/2/441DOI Listing

Publication Analysis

Top Keywords

time discretization
12
diffusion mri
8
mri signal
8
numerical simulation
4
simulation diffusion
4
mri signals
4
signals adaptive
4
adaptive time-stepping
4
time-stepping method
4
method mri
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!