Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCEP.113.001131 | DOI Listing |
J Cardiovasc Electrophysiol
February 2020
Department of Cardiology, Westmead Hospital, Sydney, Australia.
Introduction: Minimal data exist on the Advisor HD Grid (HDG) catheter and the Precision electroanatomic mapping (EAM) system for ventricular arrhythmia (VA) procedures. Using the HDG catheter, the EAM uses the high-density (HD) wave mapping and best duplicate software to compare the maximum peak-to-peak bipolar voltages within a small zone independent of wavefront direction and catheter orientation. This study aimed to summarize the procedural experience for VAs using the HDG catheter.
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
July 2018
Department of Research Development Education, CCEP Center Taufkirchen, Taufkirchen, Germany.
Inappropriate sinus tachycardia (IST) is a rare type of arrhythmia that is currently difficult to treat successfully. The effects of laser catheter applications aimed at the sinus nodal area were tested experimentally and the technique was used for the treatment of IST. Continuous-wave, mapping-guided 1,064 nm neodymium-doped yttrium aluminum garnet laser applications at 15 W (9.
View Article and Find Full Text PDFNeurogastroenterol Motil
January 2018
Department of Surgery, University of Auckland, Auckland, New Zealand.
Background: Gastric slow wave dysrhythmias are accompanied by deviations in frequency, velocity, and extracellular amplitude, but the inherent association between these parameters in normal activity still requires clarification. This study quantified these associations using a joint experimental-theoretical approach.
Methods: Gastric pacing was conducted in pigs with simultaneous high-resolution slow wave mapping (32-256 electrodes; 4-7.
Circ Arrhythm Electrophysiol
December 2013
Department of Physiology, University of Maastricht, Maastricht, The Netherlands.
We have produced high transmission sub-wavelength tapered optical fibers for the purpose of whispering gallery mode coupling in fused silica microcavities at 780 nm. A detailed analysis of the fiber transmittance evolution during tapering is demonstrated to reflect precisely the mode coupling and cutoff in the fiber. This allows to control the final size, the number of guided modes and their effective index.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!