Multiaxial high-modularity spinopelvis (HMSP) fixation device in neuromuscular scoliosis: a comparative study.

Eur Spine J

Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Severance Children's Hospital, Yonsei University College of Medicine, Seoul, South Korea.

Published: March 2014

Purpose: To compare radiological and clinical results in patients operated for neuromuscular scoliosis with pelvic fixation using high-modularity spinopelvic screw (HMSP) designed by authors.

Methods: Of 54 patients with neuromuscular scoliosis, group 1 comprised of 27 patients with conventional pelvic fixation; and group 2 comprised of 27 patients using HMSP. Results were evaluated radiologically and functionally. We compared preoperative and postoperative complications, especially the loosening or breakage of spinopelvis fixation device, failure of fixation, and the change of shadow around the spinopelvis fixation device.

Results: There was no difference of correctional power, preoperative average Cobb's angle of each group was 79.8 and 75 to postoperative 30.2 and 28.3 (P < 0.05). Pelvic obliquity improved from average 18.3°-8.9° in group I and average 24.3°-12.5° in group II (P < 0.05). However, there was no difference between two groups (P > 0.05). Average blood loss was 2,698 ml in group 1 and 2,414.8 ml in group 2 (P > 0.05). Average operative time was 360 min in group 1 and 332 min in group 2 (P = 0.30). There was no difference found between two groups regarding gait and functional evaluation. On the all cases of group 1 and 2, the change of shadow around the spinopelvis fixation device was observed. There was one case of the fracture of spinopelvis fixation device in group I.

Conclusion: There was no difference of Cobb's angle and correctional power between the groups using HMSP when compared with the group using standard spinopelvis fixation device. Therefore, HMSP can be used more effectively in case of neuromuscular scoliosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940799PMC
http://dx.doi.org/10.1007/s00586-013-3048-2DOI Listing

Publication Analysis

Top Keywords

fixation device
20
spinopelvis fixation
20
neuromuscular scoliosis
16
group
12
fixation
9
pelvic fixation
8
group comprised
8
comprised patients
8
change shadow
8
shadow spinopelvis
8

Similar Publications

Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.

View Article and Find Full Text PDF

[Outcomes of Retrograde Femoral Nail Osteosynthesis of Intraarticular Fractures of the Distal Femur].

Acta Chir Orthop Traumatol Cech

January 2025

Klinika ortopedie a traumatologie pohybového ústrojí Fakultní nemocnice Plzeň.

Purpose Of The Study: Intraarticular fractures of the distal femur rank among the most severe musculoskeletal injuries. Various treatment options, such as plate osteosynthesis or retrograde nailing, can be employed. This study aims to evaluate the clinical outcomes and complications of intraarticular distal femoral fractures treated with retrograde femoral nail, with particular emphasis on C3 fractures.

View Article and Find Full Text PDF

Tenodesis of the long head of biceps is a common shoulder surgical procedure. Tenodesis can be performed either arthroscopically or open and within the glenohumeral joint, within the bicipital groove, or below the pectoralis major tendon insertion. Arthroscopic tenodesis of the biceps tendon reduces the risk of infection.

View Article and Find Full Text PDF

Inside-out repair of meniscal tears is the gold standard surgical approach; however, its use is limited by the need for a posterior incision and neurovascular risk. In this Technical Report, we present details of the all-inside arthroscopic tie-grip approach for repairing a radial tear of the midbody of the lateral meniscus using an all-inside device (TRUESPAN) and a slotted cannula. In contrast to the inside-out approach, this technique helps reduce surgical invasiveness and provides stable fixation as the vertical mattress sutures bundle the circumferential fibers and act as rip stops for the horizontal sutures.

View Article and Find Full Text PDF

Background: The Latarjet and other bony augmentation procedures are commonly used to treat anterior shoulder instability in the setting of significant glenoid bone loss. Although several fixation strategies have been reported, the biomechanical strength of these techniques remains poorly understood.

Purpose: To perform a systematic review of the biomechanical strength of glenoid bony augmentation procedures for anterior shoulder instability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!