Pulmonary vein isolation: the impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation.

Heart Rhythm

Alfred Heart Centre, Alfred Hospital, Melbourne, Victoria, Australia; Baker IDI Heart and Diabetes Research Institute, Melbourne, Victoria, Australia; Department of Cardiology, Royal Melbourne Hospital, Parkville, Victoria, Australia; Melbourne Private Hospital, Parkville, Victoria, Australia. Electronic address:

Published: April 2014

Background: Circumferential pulmonary vein (PV) isolation is the cornerstone of catheter ablation for atrial fibrillation (AF); however, PV reconnection remains problematic.

Objective: To assess the impact of PV anatomy on outcome after AF ablation.

Methods: One hundred two patients with paroxysmal AF underwent cardiac magnetic resonance (60%) or computed tomography (40%) before AF ablation. PV anatomy was classified according to the presence of common PVs, accessory PVs, PV branching pattern, and the dimensions of the PV ostia, intervenous ridges (IVRs), and the left PV-left atrial appendage ridge.

Results: Four discrete PVs were present in 48(47%) of the patients: a left common PV in 38(37%), a right common PV in 2(2%), an accessory right PV in 20(20%), and left PV in 4(4%). At a mean follow-up of 12 ± 4 months, 75 of 102 (74%) patients were free of recurrent AF. A LCPV was associated with an increase in freedom from AF (87% vs 66% for 4 PV anatomy; P = .03). Greater left IVR length (16.9 ± 3.5 mm vs 14.0 ± 3.0 mm; P ≤ .001) and width (1.4 ± 0.6 mm vs 1.1 ± 0.6 mm; P = .02) were associated with increased AF recurrence. After multivariate analysis, abnormal anatomy (LCPV or accessory PV) and left IVR length were found to be the only independent predictors of freedom from AF.

Conclusions: Four discrete PVs are present in the minority of patients with paroxysmal AF undergoing PV isolation. The presence of a LCPV is associated with an increased freedom from AF after catheter ablation. PV anatomy may in part explain the variable outcome to electrical isolation in patients with paroxysmal AF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2013.12.025DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
patients paroxysmal
12
pulmonary vein
8
vein isolation
8
atrial fibrillation
8
ablation anatomy
8
discrete pvs
8
lcpv associated
8
left ivr
8
ivr length
8

Similar Publications

Cardiac tamponade is a rare but fatal complication of catheter ablation. We are reporting a case of a 73-year-old male with ventricular tachycardia (VT) storm undergoing urgent VT ablation, who was later found to have right ventricle (RV) perforation-an unusual site for catheter ablation complication. The patient underwent isochronal late activation mapping (ILAM)-based ablation and elimination of local abnormal ventricular activities (LAVA).

View Article and Find Full Text PDF

Atrial fibrillation (AF) is the most common cardiac arrhythmia and pulmonary vein isolation (PVI) by percutaneous transcatheter ablation is its pivotal treatment. Nowadays, several techniques using different energy sources are used, such as radiofrequency (RF), cryoablation and laser ablation. A new technology that combines the strengths of different techniques has been developed, in particular having both the speed of one-shot techniques and the selectivity and precision of point-by-point RF: the RF balloon (RFB).

View Article and Find Full Text PDF

Background: Catheter ablation is an effective treatment for atrial fibrillation (AF). Pulsed field ablation (PFA) has emerged as a novel energy modality, which relies on high-voltage electric fields to achieve cardiac tissue ablation. Data on its efficacy in the elderly are scarce.

View Article and Find Full Text PDF

Background: Pulsed field ablation (PFA) for paroxysmal atrial fibrillation (AF) has been gaining worldwide acceptance due to its efficacy and safety. A variable loop circular catheter (VLCC, VARIPULSE, Biosense Webster, Inc.) for PFA, recently launched in Japan, includes a Tissue Proximity Indication (TPI) feature to monitor catheter-tissue contact via impedance.

View Article and Find Full Text PDF

Introduction: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia worldwide. Although catheter ablation is the most efficacious therapy, relapses occur frequently (30%) in the first year after ablation. Novel biomarkers of recurrence are needed for a better prediction of recurrence and management of AF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!