Introduction: The optimal suction pressure during endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) remains to be determined. The aim of this study was to compare suction pressures for performance in collecting sufficient tissue specimens from mediastinal and hilar lymph nodes during EBUS-TBNA.
Methods: Retrospective analysis of consecutive patients with mediastinal and hilar lymphadenopathy who underwent EBUS-TBNA over a 3-year period. Results from patients who underwent EBUS-TBNA using a dedicated 20-mL VacLoc (Merit Medical Systems, Inc, South Jordan, UT) syringe (conventional method, group C) were compared with results from patients in whom a disposable 30-mL syringe (high pressure group, group H) was used. The yield for sufficient histologic specimen retrieval and amount of tissue obtained were compared between the 2 groups.
Results: Of 178 patients who underwent EBUS-TBNA, 131 had lung cancer confirmed by EBUS-TBNA: 35 in group C and 96 in group H. There were 7 patients in group C and 6 in group H who received final diagnoses by cytology alone. There were 28 in group C and 90 in group H who were diagnosed by both cytology and histology. There was a statistically significant difference between the groups in terms of the rate of sufficient sampling for histological specimens (p = 0.04). The H group revealed a tissue area approximately twice that of the C group (p = 0.003). There were no major procedure-related complications in either group.
Conclusion: Higher suction pressures with larger syringe volumes during EBUS-TBNA may be useful for safely collecting sufficient tissue specimens.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3855538 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0082787 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!