A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of occupational exposure in magnetic resonance sites. | LitMetric

Evaluation of occupational exposure in magnetic resonance sites.

Radiol Med

S.A.S.T.A.S Department-Section of Protezionistica A.S.S.I, University of Messina, Viale Gazzi-Policlinico Universitario, Torre Biologica, 98125, Messina, Italy,

Published: March 2014

AI Article Synopsis

  • The study evaluates MRI workers' exposure to static magnetic fields by aggregating magnetic flux density over time and proposing a precautionary weight based on Italian regulations.
  • The methodology involved using Hall-sensor probes and statistical tests to ensure data accuracy, with measurements taken from various MRI machines.
  • Results show that MRI staff did not exceed the legal limit of 200 mT·h, but higher magnetic field strengths led to overestimation of exposure; a dedicated dose card is recommended for tracking long-term exposure.

Article Abstract

Purpose: In an attempt to evaluate the exposure level of magnetic resonance imaging (MRI) workers to static magnetic fields, the isotropic magnetic flux density values were integrated over time to produce the cumulative exposure. To protect occupational staff a further precautionary step is proposed by introducing a weighting function incorporating the limits imposed by the Italian legislation. The results obtained should be reported, at the end of each working day, on a special dose card, in order to record each worker's exposure to the static magnetic field. Moreover, this dose card could be an important tool if long-term effects occur because it provides a complete history of the occupational exposure in an MRI site.

Materials And Methods: To conduct measurements, three Hall-sensor probes were used. The consistency of experimental data, tools and methodologies used was evaluated by performing the Kruskal-Wallis test. Finally, the weighted magnitude of the magnetic flux density was integrated over time to obtain global exposure.

Results: Measurements were performed on different MRI scanners ranging from 0.25 up to 3.0 T. The results obtained were compared with the 200 mT·h, which represents the upper limit of the Italian regulation. In no case was the 200 mT·h per day exposure exceeded: however, when the strength of the magnetic field was >200 mT the weighted function overestimated the exposure, so that it represents a highly precautionary measure taking into account possible acute and long-term effects. In addition, from the data recorded during patient positioning operations by MRI staff the dB/dt curve was obtained.

Conclusions: The areas obtained from the integral of the weighted static magnetic field strength over time can be indicative of the global exposure of the occupational staff. These values should be reported on a special dose card that could be considered as an important tool if long-term effects occur because it provides a complete history of the occupational exposure in an MRI site.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-013-0324-5DOI Listing

Publication Analysis

Top Keywords

occupational exposure
12
static magnetic
12
dose card
12
magnetic field
12
long-term effects
12
exposure
9
magnetic
8
magnetic resonance
8
magnetic flux
8
flux density
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!