Purpose: To establish reference data on the dimensions of C2 lamina to guide the use of translaminar screws with Wright's technique and a modified technique for pediatric patients in different age groups.

Methods: 113 pediatric patients were divided into six age groups, and their cervical vertebrae were studied on CT scans. Laminar height, width, length and screw angle were measured. Statistical analysis was performed using Student t tests, Pearson's correlation and linear regression analysis.

Results: Mean laminar height was 10.95 ± 2.81 mm, and mean width was 6.01 ± 0.90 mm. For Wright's technique, mean laminar length was 30.65 ± 3 mm, and the screw angle was 56.02° ± 3.62°. For the modified technique, mean laminar length was 22.07 ± 2.38 mm, and the screw angle was 67.40° ± 3.39°. 95.6% (108/113) of the children could insert a screw into the lamina (laminar width ≥ 4.5 mm), 72.6% (82/113) could accept bilateral translaminar screws (laminar width ≥ 4.5 mm and laminar height ≥ 9 mm).

Conclusion: Our investigation provides insight into the anatomy of C2 lamina in six pediatric age groups. Compared to adults, the benefits of C2 translaminar screws fixation are more obvious in the pediatric spine which has a large C2 lamina. Compared to Wright's technique, the modified technique should insert a screw with bigger insert angle and shorter screw length.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940813PMC
http://dx.doi.org/10.1007/s00586-013-3130-9DOI Listing

Publication Analysis

Top Keywords

wright's technique
16
modified technique
16
technique modified
12
translaminar screws
12
laminar height
12
screw angle
12
technique
8
technique pediatric
8
pediatric patients
8
age groups
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!