Cluster analysis is usually the first step adopted to unveil information from gene expression microarray data. Besides selecting a clustering algorithm, choosing an appropriate proximity measure (similarity or distance) is of great importance to achieve satisfactory clustering results. Nevertheless, up to date, there are no comprehensive guidelines concerning how to choose proximity measures for clustering microarray data. Pearson is the most used proximity measure, whereas characteristics of other ones remain unexplored. In this paper, we investigate the choice of proximity measures for the clustering of microarray data by evaluating the performance of 16 proximity measures in 52 data sets from time course and cancer experiments. Our results support that measures rarely employed in the gene expression literature can provide better results than commonly employed ones, such as Pearson, Spearman, and euclidean distance. Given that different measures stood out for time course and cancer data evaluations, their choice should be specific to each scenario. To evaluate measures on time-course data, we preprocessed and compiled 17 data sets from the microarray literature in a benchmark along with a new methodology, called Intrinsic Biological Separation Ability (IBSA). Both can be employed in future research to assess the effectiveness of new measures for gene time-course data.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TCBB.2013.9DOI Listing

Publication Analysis

Top Keywords

proximity measures
16
microarray data
16
measures clustering
12
gene expression
12
data
9
expression microarray
8
proximity measure
8
clustering microarray
8
data sets
8
time course
8

Similar Publications

Blood-based biomarkers have been revolutionizing the detection, diagnosis and screening of Alzheimer's disease. Specifically, phosphorylated-tau variants (p-tau, p-tau and p-tau) are promising biomarkers for identifying Alzheimer's disease pathology. Antibody-based assays such as single molecule arrays immunoassays are powerful tools to investigate pathological changes indicated by blood-based biomarkers and have been studied extensively in the Alzheimer's disease research field.

View Article and Find Full Text PDF

Objective: Previous studies have hinted at an association between water exposure and the development of ALS. However, proximity measures to these water sources have been limited to questionnaires or large buffers due to a lack of fine geospatial measures. They also do not distinguish the various classes of hydrographic features.

View Article and Find Full Text PDF

Flexible Eyelid Pressure and Motion Dual-Mode Sensor Using Electric Breakdown-Induced Piezoresistivity and Electrical Potential Sensing.

ACS Appl Mater Interfaces

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing 100730, China.

Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies.

View Article and Find Full Text PDF

NLRP3 is a BMI-independent mediator of stable COPD.

BMC Pulm Med

January 2025

İzmir International Biomedicine and Genome Institute, Dokuz Eylül University, İzmir, Türkiye.

Purpose: The inflammatory response in animal models of chronic obstructive pulmonary disease (COPD) is activated by the NLR-family-pyrin-domain-containing-3 (NLRP3) inflammasome pathway, which is also known to play a role in obesity-related inflammation. The NLRP3/caspase-1/interleukin (IL)-1β pathway might be involved in the progression of COPD with increasing body mass index. To our knowledge, no previous studies have explored the role of NLRP3 inflammasome markers in linking COPD and obesity.

View Article and Find Full Text PDF

Objective: To identify the sonomorphological appearance and to measure the thickness of the piriformis muscle (PM) and the proximal portion of the sacral nerve roots S1-S3 in healthy premenopausal women.

Materials And Methods: This prospective multicentric observational study included a consecutive series of women undergoing transvaginal sonography (TVS) at two tertiary gynecological referral centers. Standardized assessment of the pelvic organs was performed followed by an attempt to visualize the right and left PM and sacral nerve roots S1-S3 at their origin in proximity to the sacral neuroforamen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!