This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2013.11.039DOI Listing

Publication Analysis

Top Keywords

wireless transceiver
12
sodium
8
potentiometric sodium
8
tattoo-based potentiometric
8
sensor coupled
8
monitoring sodium
8
human perspiration
8
tattoo sensor
8
sweat sodium
8
sodium dynamics
8

Similar Publications

Free space optical communication (FSOC) technology can be used for data transmission between ocean islands as backup wireless communication networks to cope with traffic surges and emergencies. In this paper, we experimentally demonstrate the results of a 24-h real-time single-wavelength 2.5-Gbps FSOC between two islands 29 km apart at a low altitude with low complexity.

View Article and Find Full Text PDF

The millimeter-wave wireless transmission system is widely regarded as a promising solution for applications of future 6G communication. This paper presents an experimental comparison between all-optical and all-electric receivers for millimeter-wave communication systems over a 15 m wireless link and demonstrates 200 m and 2 km real-time uncompressed HD video transmission using an all-optical transceiver at 100 GHz. The systems leverage photonics-assisted heterodyne beating techniques at the transmitter, while the receivers employ either an avalanche photodiode (APD)-based all-optical approach or an envelope detection-based all-electric approach.

View Article and Find Full Text PDF

New Design Scheme for and Application of Fresnel Lens for Broadband Photonics Terahertz Communication.

Sensors (Basel)

November 2024

State Key Laboratory of ASIC and System, Key Laboratory for Information Science of Electromagnetic Waves (MoE), School of Information Science and Technology, Fudan University, Shanghai 200433, China.

In terahertz communication systems, lens antennas used in transceivers are basically plano-convex dielectric lenses. The size of a plano-convex lens increases as the aperture increases, and thinner lenses have longer focal lengths. Through theory and simulation, we designed a Fresnel lens suitable for the terahertz band to meet the requirements of large aperture and short focal length, and simulated the performance, advantages, and disadvantages of the terahertz Fresnel lens.

View Article and Find Full Text PDF

Robust Magnetoelectric Backscatter Communication System for Bioelectronic Implants.

Res Sq

December 2024

Department of Electrical and Computer Engineering, Rice University, 6100 Main St, Houston, TX, 77005.

Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.

View Article and Find Full Text PDF

Comprehensive electrical models for a wireless sensor network device.

Heliyon

December 2024

Transilvania University of Brașov, Department of Electronics and Computers, Faculty of Electrical Engineering and Computer Science, Brasov, 500036, Romania.

This paper proposes a novel circuit model of a Wireless Sensor Network (WSN) device. The model is designed to accurately represent the behavior of a WSN device operating in a duty cycle, capturing the essential characteristics of its components, including the microcontroller, sensor, transceiver, and power supply. The proposed model incorporates static and dynamic power consumption aspects, reflecting the energy usage patterns during various operational states such as sensing, processing, and communication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!