A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cardiac implantable electronic device infections: incidence, risk factors, and the effect of the AigisRx antibacterial envelope. | LitMetric

Background: Cardiac implantable electronic device (CIED) infection is associated with morbidity and mortality.

Objectives: To determine the incidence and risk factors for CIED infection, to develop a scoring index for risk stratification, and to analyze the effect of the AIGISRx envelope on infection rates.

Methods: Consecutive patients who underwent a CIED procedure were identified and surveyed for 6 months for the development of an infection necessitating removal of all implanted hardware.

Results: In the pre-envelope era, an infection occurred in 25 (1.5%) of 1651 patients. After its availability, an envelope was used in 275 (22%) of 1240 patients; an infection occurred in 8 (0.6%) patients in this era (P = .029 vs pre-envelope). In the overall cohort of 2891 patients, the infection rate was 1.2% and 3.5% in patients with an implantable cardioverter-defibrillator device and those with a cardiac resynchronization therapy defibrillator device, respectively (P = .018); in these patients, 7 independent risk factors predicted infection: early pocket re-exploration, male sex, diabetes, upgrade procedure, heart failure, hypertension, and glomerular filtration rate < 60 mL/min. A composite risk score (0-25; C index 0.72; 95% confidence interval 0.61-0.83) was created by weight, adjusting these 7 factors: 3 groups emerged-low risk (score 0-7; 1% infection), medium risk (score 8-14; 3.4% infection), and high risk (score ≥15; 11.1% infection). The envelope reduced infections by 79% and 100% in the medium- and high-risk groups, respectively.

Conclusions: CIED infection most commonly occurred in patients with an implantable cardioverter-defibrillator device and those with a cardiac resynchronization therapy defibrillator device. A composite score based on clinical variables appeared feasible for infection risk stratification. The AIGISRx envelope significantly lowered the risk of CIED infection. Randomized clinical data are warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2013.12.013DOI Listing

Publication Analysis

Top Keywords

cied infection
16
risk score
16
infection
14
risk factors
12
risk
10
cardiac implantable
8
implantable electronic
8
electronic device
8
incidence risk
8
risk stratification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!