Objectives: This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).

Background: Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.

Methods: Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.

Results: Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.

Conclusions: Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2013.07.012DOI Listing

Publication Analysis

Top Keywords

newer-generation des
36
myocardial infarction
16
composite endpoint
16
compared bms
12
des
11
newer-generation
10
newer-generation drug-eluting
8
bare-metal stents
8
st-segment elevation
8
elevation myocardial
8

Similar Publications

Importance: Drug-coated balloon (DCB) angioplasty has emerged as an alternative to drug-eluting stent (DES) implantation for percutaneous coronary intervention (PCI) in patients with coronary in-stent restenosis (ISR) as well as de novo coronary artery disease.

Observations: DCBs are balloons coated with antiproliferative agents and excipients, whose aim is to foster favorable vessel healing after appropriate lesion preparation. By providing homogeneous antiproliferative drug delivery in the absence of permanent foreign body implantation, DCBs offer multiple advantages over DES, including preservation of vessel anatomy and function and positive vessel remodeling.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) has been identified as a marker of advanced cardiac damage in aortic stenosis patients. However, the factors associated with poorer outcomes among AF patients in contemporary TAVR practice, particularly regarding mortality and heart failure (HF)-related hospitalizations, remain largely unknown.

Methods: Multicenter study including consecutive patients with a history of AF, evaluating the clinical outcomes and predictors of mortality, and HF-related hospitalization, who underwent TAVR with newer-generation devices using balloon or self-expandable valves.

View Article and Find Full Text PDF

Background: Calcified nodule (CN) is a phenotypic feature of calcified plaques which causes acute coronary syndrome (ACS). Recent studies reported that culprit lesions harboring CN has been shown to increase a risk of repeat revascularization after percutaneous coronary intervention (PCI) with the implantation of newer-generation drug-eluting stent (DES) or debulking device. Mechanistically, a re-protrusion of CN into the lumen has been considered as an important cause associated with repeat revascularization after PCI.

View Article and Find Full Text PDF

Due to limited published data, we investigated 3-year outcomes according to left ventricular ejection fraction (LVEF) in patients older and younger than 75 years with non-ST-segment elevation myocardial infarction (NSTEMI) who underwent successful newer-generation drug-eluting stent (DES) implantation. This research analyzed the data of 4558 patients (1032 older adults [≥75 years] and 3526 younger adults [<75 years]) from the Korea Acute MI Registry-NIH. We further divided the older group based on LVEF: heart failure (HF) with reduced EF (HFrEF, ≤40%, n = 196; group A), HF with mildly reduced EF (HFmrEF, 41-49%, n = 228; group B), and HF with preserved EF (HFpEF, ≥50%, n = 608; group C).

View Article and Find Full Text PDF

Background: Newer generation ultrathin strut stents are associated with less incidence of target lesion failure (TLF) in patients undergoing percutaneous coronary intervention (PCI) in the short term. However, its long-term effect on different cardiovascular outcomes remains unknown.

Objectives: We aim to identify the effects of newer-generation ultrathin-strut stents vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!