Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: To describe the time course of myocardial scarring after transapical-transcatheter aortic valve implantation (TA-TAVI) with the Edwards SAPIEN XT™ and the Edwards SAPIEN™ prosthesis in a 3-month follow-up study using cardiac magnetic resonance imaging (CMR).
Methods: In 20 TA-TAVI patients, CMR was performed at discharge and 3 months (3M). Cine-MRI was used for left ventricular (LV) functional assessment, and late gadolinium enhancement (LGE) imaging was employed for detecting the presence of myocardial scarring. Special attention was given to any artifacts caused by the prosthesis, which were consequently defined using a three-grade artifact scale.
Results: We systematically reported the presence of small LGE hyperintensity relating to the apical segment, with no variation found between discharge and 3M (2.8±1.6g vs. 2.35±1.1g). LV ejection fraction, end-diastolic, and end-systolic volumes did not significantly vary. A small area of apical akinesia was observed, with no improvement at follow-up. Whereas the Edwards SAPIEN XT™ prosthesis and the Edwards SAPIEN™ prosthesis are both constituted by metallic stenting structure, the Edwards SAPIEN™ was responsible for a larger signal void, thus potentially limiting the diagnostic performance of CMR.
Conclusions: CMR may be performed safely in the context of TA-TAVI. The presence of a very small apical infarction correlating with focal akinesia was observed. As expected, the Edwards SAPIEN XT™ prosthesis was shown to be particularly suitable for CMR assessment.