Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Re-irradiation is a reasonable second treatment option for patients with recurrent malignant glioma (MG) after previous radio(chemo)therapy. However, only limited data is available allowing for a precise selection of patients suitable for re-treatment in regard to safety and efficacy.
Methods: Using the department database, 58 patients with two courses of percutaneous radiation were identified. Besides classical dose-volume histogram (DVH) parameters equivalent uniform dose (EUD) values were calculated for the tumor and organs at risk (OARs), retrospectively analyzed and correlated to survival outcome parameters. Cumulative EUD values were also calculated in all cases where previous OAR DVHs were available.
Results: Median follow-up was 265 days and no relevant toxicity was observed after re-irradiation in our patient cohort during follow-up. Time interval between first and second irradiation was regularly above 6 months. As a conservative estimation of the cumulative EUD to the OARs, the EUDs of first and second irradiation were added. Median cumulative EUD to the optic chiasm was 48.8 Gy (range, 2.5-76.5 Gy), 57.4 Gy (range, 2.7-75.3 Gy) to the brainstem, 20.9/22.1 Gy (range, 0.0-68.3 Gy) to the right/left optic nerve and 73.8 Gy (range, 64.9-77.3 Gy) to the brain. No correlation between treated volume and survival was seen.
Conclusions: This study provides retrospective estimates on cumulative doses at the OARs. EUD values are derived and may serve as reference for further studies, including planning studies where specific constraints are needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029146 | PMC |
http://dx.doi.org/10.1186/1748-717X-8-287 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!