Quantum versus classical foundation of statistical mechanics under experimentally realistic conditions.

Phys Rev E Stat Nonlin Soft Matter Phys

Fakultät für Physik, Universität Bielefeld, 33615 Bielefeld, Germany.

Published: November 2013

Focusing on isolated macroscopic systems, described in terms of either a quantum mechanical or a classical model, our two key questions are how far does an initial ensemble (usually far from equilibrium and largely unknown in detail) evolve towards a stationary long-time behavior (equilibration) and how far is this steady state in agreement with the microcanonical ensemble as predicted by statistical mechanics (thermalization). A recently developed quantum mechanical treatment of the problem is briefly summarized, putting particular emphasis on the realistic modeling of experimental measurements and nonequilibrium initial conditions. Within this framework, equilibration can be proven under very weak assumptions about those measurements and initial conditions, while thermalization still requires quite strong additional hypotheses. An analogous approach within the framework of classical mechanics is developed and compared with the quantum case. In particular, the assumptions to guarantee classical equilibration are now rather strong, while thermalization then follows under relatively weak additional conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevE.88.052114DOI Listing

Publication Analysis

Top Keywords

statistical mechanics
8
quantum mechanical
8
initial conditions
8
quantum
4
quantum versus
4
classical
4
versus classical
4
classical foundation
4
foundation statistical
4
mechanics experimentally
4

Similar Publications

Background: Acute kidney injury (AKI) is common in critically ill patients and is associated with increased morbidity and mortality. Its complications often require renal replacement therapy (RRT). Invasive mechanical ventilation (IMV) and infections are considered risk factors for the occurrence of AKI.

View Article and Find Full Text PDF

This study explores the development of electrospun nanofibers incorporating bioactive compounds from (Ashwagandha) root extract, focusing on optimizing extraction conditions and nanofiber composition to maximize biological activity and application potential. Using the Design of Experiment (DoE) approach, optimal extraction parameters were identified as 80% methanol, 70 °C, and 60 min, yielding high levels of phenolic compounds and antioxidant activity. Methanol concentration emerged as the critical factor influencing phytochemical properties.

View Article and Find Full Text PDF

Evaluating ChatGPT-4 for the Interpretation of Images from Several Diagnostic Techniques in Gastroenterology.

J Clin Med

January 2025

Precision Medicine Unit, Department of Gastroenterology, São João University Hospital, Alameda Professor Hernâni Monteiro, 4200-427 Porto, Portugal.

Several artificial intelligence systems based on large language models (LLMs) have been commercially developed, with recent interest in integrating them for clinical questions. Recent versions now include image analysis capacity, but their performance in gastroenterology remains untested. This study assesses ChatGPT-4's performance in interpreting gastroenterology images.

View Article and Find Full Text PDF

: Clinically inactive corneal scars have repeatedly been shown to exhibit histological inflammation. This study aimed to evaluate the degree of histological inflammation in clinically inactive corneal scars of different origins and its correlation with graft rejection and failure following penetrating keratoplasty. : The study included 205 primary corneal explants with clinically inactive central scars resulting from herpes simplex virus keratitis (HSV, = 55), keratoconus ( = 39), mechanical trauma ( = 27), scrophulosa ( = 22) or other/unknown causes ( = 62).

View Article and Find Full Text PDF

: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!