Background: In this study, early outcomes of the spinous process wiring with vertical strut (SPWVS) were compared with that of standard pedicle screw and rod (PSR) in our patients.
Materials And Methods: We obtained patients' bio-data, diagnosis, investigations, cost of implant, operative circumstances, complications, and outcomes from clinical documentation. Outcome measures, including postoperative infection and persistent/recurrent instabilities, implant related problems, operative blood loss and time and cost, were compared in the two groups of patients.
Results: Forty one (M:F-0.9:1) patients had PSR and 35 (M:F-2.2:1) had SPWVS. There was no difference in the occurrence of post-operative instability ( P = 0.630), surgical site infection ( P ≥ 0.416), neurological deficits ( P ≥ 0.461) and implant related complications ( P ≥ 0.461) in the two groups of patients. Cost of implant in the PSR group range from N138,000 (for 2 level fusion) (1USD = N159) to N246,000 (for 4 level fusion) with an average of N192,000 (Standard deviation [SD] N44,090.81) depending on the number of level fused while the cost of implant for SPWVS was N8,000 irrespective of the number of level of fusion being carried out ( P = 0.000). Mean estimated blood loss intra-operatively was higher for PSR (761.33 [SD 396.24] ml) than SPWVS (524.58 [SD 504.70] ml) ( P = 0.005). Mean operation time was 397.17 (SD 122.183) min and 249.44 (SD 130.31) min PSR and SPWVS ( P = 0.000).
Conclusion: SPWVS appears to be a good alternative to PSR, especially in our resource limited environment, in view of similar post-operative infection rate, implant complication, stability and post-operative neurological deterioration as well as shorter operation time, less estimated blood loss and much cheaper cost of implant in the former.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4103/1119-3077.122838 | DOI Listing |
Eur J Dent Educ
January 2025
Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA.
Introduction: Objective Structured Clinical Examinations (OSCEs) serve as a reliable assessment tool for clinical and competency evaluation. Traditional OSCEs, involving live patients, present logistical challenges and evoke student anxiety. In an effort to create a comprehensive clinical series of examinations, electronic OSCEs (e-OSCEs) were developed for assessing clinical competencies in prosthodontics at a large dental school.
View Article and Find Full Text PDFSci Rep
January 2025
Medical Oncology Department, Central University Hospital of Asturias, Oviedo, Spain.
Totally implantable central venous catheters (CVCs) are widely used in the management of patients with malignant diseases. Conventionally, port implantations were carried out by general surgeons and vascular radiologists. In recent years, the medical staff of the Medical Oncology department at the Central University Hospital of Asturias (HUCA) has developed a simplified methodology for the routine implantation of these devices.
View Article and Find Full Text PDFJ Dent Sci
January 2025
School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Background/purpose: Early osseointegration of titanium (Ti) dental implants relies on the surface topography. Surface modification of Ti seeks to enhance bone regeneration around implants. Acid etching is the simple, less technique sensitive and cost-effective technique for surface treatment.
View Article and Find Full Text PDFSurg Endosc
January 2025
Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.
Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.
View Article and Find Full Text PDFAnal Chem
January 2025
Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!